FabDigitFabDigit

Copper Alloy C12200 vs C19800

Copper Alloy · grade comparison

Copper Alloy C12200 and C19800 are both copper alloy grades. C19800 is the stronger of the two: yield strength 495 MPa (71.8 ksi) against 76 MPa (11 ksi) for C12200, about 6.5 times as much; tensile strength follows at 520 MPa (75.4 ksi) vs 235 MPa (34.1 ksi). In exchange, C12200 is the more ductile: elongation 45% versus 4% for C19800. C12200 runs hotter in service (200°C vs 150°C continuous) and C12200 conducts heat better (339 W/m·K vs 180 W/m·K). On the shop floor, C12200 welds better (excellent vs fair).

C12200Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C19800Choose it when strength drives the design.

C12200 vs C19800: properties

C12200C19800

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

117 GPa17 Msi
120 GPa17.4 Msi

Shear Modulus

44 GPa6.4 Msi
45 GPa6.5 Msi

Bulk Modulus

140 GPa20.3 Msi
135 GPa19.6 Msi

Tensile Strength (Ultimate)

235 MPa34.1 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

76 MPa11 ksi
495 MPa71.8 ksi

Elongation at Break

45%
4%

Reduction in Area

75%
—

Shear Strength

150 MPa21.8 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

76 MPa11 ksi
200 MPa29 ksi

Hardness, Brinell

45 HB
—

Hardness, Rockwell B

—
82 HRB

Hardness, Vickers

—
165 HV

Same in both: Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Density

8.94 g/cm³0.32 lb/in³
8.89 g/cm³0.32 lb/in³

Melting Point (Solidus)

1,083°C1,981 °F
1,020°C1,868 °F

Liquidus Temperature

1,083°C1,981 °F
1,055°C1,931 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

339 W/m·K196 BTU/hr·ft·°F
180 W/m·K104 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

17 µm/m·K9.4 µin/in·°F
17.6 µm/m·K9.8 µin/in·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

85 % IACS
45 % IACS

Electrical Resistivity

2.03×10⁻⁸ Ω·m0.799 µΩ·in
3.83×10⁻⁸ Ω·m1.51 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.3 V
-0.25 V

Corrosion Resistance

70 / 100
65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
22 / 100

Weldability

85 / 100
45 / 100

Formability (cold)

98 / 100
45 / 100

Brazeability / Solderability

100 / 100
85 / 100

Polishability

80 / 100
70 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20%

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

55 MJ/kg23,646 BTU/lb
58 MJ/kg24,936 BTU/lb

Embodied Water

250 L/kg30 gal/lb
260 L/kg31.2 gal/lb

Same in both: Embodied Carbon (primary production) 3.8 kg CO₂/kg · Typical Recycled Content 35%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

26 kN·m/kg
58 kN·m/kg

Specific Stiffness (E / density)

13.1 MN·m/kg
13.5 MN·m/kg

Modulus of Resilience

25 kJ/m³
1,021 kJ/m³

Thermal Diffusivity

98.5 mm²/s
52.6 mm²/s

Thermal Shock Resistance Index

40
44

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC12200C19800

Manufacturing and finishing

CapabilityC12200C19800
CNC machiningYes—
Sheet metalYes—
Default conditionO—
Relative cost$$$$ High$$$$ High
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
Chrome PlatingYes—
ElectropolishingYes—
Nickel PlatingYes—
PaintingYes—
Tin PlatingYes—

They share 4 finishes: Copper Plating, Electroless Nickel (EN), Gold Plating, Silver Plating.

C12200 vs C19800 — frequently asked

Is C19800 stronger than C12200?

Yes. C19800 has a typical yield strength of 495 MPa (71.8 ksi) against 76 MPa (11 ksi) for C12200 — about 6.5 times as much. Tensile strength is 520 MPa (75.4 ksi) vs 235 MPa (34.1 ksi).

Which is cheaper, C12200 or C19800?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, C12200 or C19800?

C12200. Its weldability rates excellent (85/100) against fair (45/100) for C19800.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C12200 and C19800 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.