FabDigitFabDigit

Copper Alloy C11600-H02 vs C11600-H04

Copper Alloy · C11600 temper comparison

C11600-H02 and C11600-H04 are two conditions of the same copper alloy grade, C11600: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C11600-H04 is the stronger of the two: yield strength 310 MPa (45 ksi) against 250 MPa (36.3 ksi) for C11600-H02, about 24% more; tensile strength follows at 345 MPa (50 ksi) vs 290 MPa (42.1 ksi). In exchange, C11600-H02 is the more ductile: elongation 14% versus 6% for C11600-H04, and C11600-H04 is harder (95 HB vs 80 HB). C11600-H04 is stiffer (128 GPa vs 117 GPa).

C11600-H02Choose it when the part is bent, formed or impact-loaded.

C11600-H04Choose it when strength drives the design.

C11600-H02 vs C11600-H04: properties

C11600-H02C11600-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

117 GPa17 Msi
128 GPa18.6 Msi

Tensile Strength (Ultimate)

290 MPa42.1 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
310 MPa45 ksi

Elongation at Break

14%
6%

Reduction in Area

60%
55%

Shear Strength

185 MPa26.8 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
110 MPa16 ksi

Hardness, Brinell

80 HB
95 HB

Hardness, Rockwell B

40 HRB
50 HRB

Hardness, Vickers

90 HV
108 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

385 W/m·K222 BTU/hr·ft·°F
382 W/m·K221 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

98 % IACS
97 % IACS

Electrical Resistivity

1.76×10⁻⁸ Ω·m0.693 µΩ·in
1.78×10⁻⁸ Ω·m0.701 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
25%

Formability (cold)

60 / 100
40 / 100

Same in both: Weldability 35 / 100 · Brazeability / Solderability 92 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC11600

C11600-H02 vs C11600-H04 — frequently asked

Is C11600-H04 stronger than C11600-H02?

Yes. C11600-H04 has a typical yield strength of 310 MPa (45 ksi) against 250 MPa (36.3 ksi) for C11600-H02 — about 24% more. Tensile strength is 345 MPa (50 ksi) vs 290 MPa (42.1 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H02 is the default C11600 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C11600-H02 or C11600-H04?

C11600-H04, by a small margin. Both rate poor for machinability — 30/100 against 25/100 for C11600-H02.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C11600-H02 and C11600-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.