C11000-H04 and C11000-HIP are two conditions of the same copper alloy grade, C11000: H04 (full hard) versus HIP (hot isostatic pressed). The chemistry is identical, so every difference below comes from the condition. C11000-H04 is the stronger of the two: yield strength 310 MPa (45 ksi) against 75 MPa (10.9 ksi) for C11000-HIP, about 4.1 times as much; tensile strength follows at 345 MPa (50 ksi) vs 220 MPa (31.9 ksi). In exchange, C11000-HIP is the more ductile: elongation 45% versus 6% for C11000-H04, and C11000-H04 is harder (100 HB vs 47 HB). C11000-H04 is stiffer (128 GPa vs 115 GPa) and C11000-HIP runs hotter in service (200°C vs 120°C continuous).

C11000-H04Choose it when strength drives the design.

C11000-HIPChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C11000-H04 vs C11000-HIP: properties

C11000-H04C11000-HIP

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

128 GPa18.6 Msi
115 GPa16.7 Msi

Tensile Strength (Ultimate)

345 MPa50 ksi
220 MPa31.9 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
75 MPa10.9 ksi

Elongation at Break

6%
45%

Reduction in Area

45%
65%

Shear Strength

200 MPa29 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

117 MPa17 ksi
76 MPa11 ksi

Hardness, Brinell

100 HB
47 HB

Hardness, Vickers

110 HV
52 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Density

8.94 g/cm³0.32 lb/in³
8.9 g/cm³0.32 lb/in³

Same in both: Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

380 W/m·K220 BTU/hr·ft·°F
385 W/m·K222 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
200°C392 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

97 % IACS
99 % IACS

Electrical Resistivity

1.71×10⁻⁸ Ω·m0.673 µΩ·in
1.74×10⁻⁸ Ω·m0.685 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.32 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

30%
20%

Formability (cold)

45 / 100
90 / 100

Same in both: Machinability 25 / 100 · Weldability 35 / 100 · Castability 40 / 100 · Brazeability / Solderability 92 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC11000

C11000-H04 vs C11000-HIP — frequently asked

Is C11000-H04 stronger than C11000-HIP?

Yes. C11000-H04 has a typical yield strength of 310 MPa (45 ksi) against 75 MPa (10.9 ksi) for C11000-HIP — about 4.1 times as much. Tensile strength is 345 MPa (50 ksi) vs 220 MPa (31.9 ksi).

Which condition does FabDigit quote by default, H04 or HIP?

O is the default C11000 condition in the FabDigit quote flow (neither H04 nor HIP). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C11000-H04 over C11000-HIP?

Pick C11000-H04 when strength drives the design. Pick C11000-HIP when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C11000-H04 and C11000-HIP side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.