C10700-H04 and C10700-O60 are two conditions of the same copper alloy grade, C10700: H04 (full hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C10700-H04 is the stronger of the two: yield strength 310 MPa (45 ksi) against 70 MPa (10.2 ksi) for C10700-O60, about 4.4 times as much; tensile strength follows at 345 MPa (50 ksi) vs 225 MPa (32.6 ksi). In exchange, C10700-O60 is the more ductile: elongation 45% versus 6% for C10700-H04, and C10700-H04 is harder (95 HB vs 45 HB). C10700-O60 runs hotter in service (300°C vs 250°C continuous).

C10700-H04Choose it when strength drives the design.

C10700-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C10700-H04 vs C10700-O60: properties

C10700-H04C10700-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

345 MPa50 ksi
225 MPa32.6 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
70 MPa10.2 ksi

Elongation at Break

6%
45%

Reduction in Area

55%
75%

Shear Strength

200 MPa29 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
76 MPa11 ksi

Hardness, Brinell

95 HB
45 HB

Hardness, Rockwell B

52 HRB
40 HRB

Hardness, Vickers

105 HV
50 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

386 W/m·K223 BTU/hr·ft·°F
391 W/m·K226 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
300°C572 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

99 % IACS
101 % IACS

Electrical Resistivity

1.74×10⁻⁸ Ω·m0.685 µΩ·in
1.71×10⁻⁸ Ω·m0.672 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

25%
20%

Weldability

60 / 100
62 / 100

Formability (cold)

60 / 100
98 / 100

Same in both: Machinability 30 / 100 · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 380 L/kg45.5 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC10700

C10700-H04 vs C10700-O60 — frequently asked

Is C10700-H04 stronger than C10700-O60?

Yes. C10700-H04 has a typical yield strength of 310 MPa (45 ksi) against 70 MPa (10.2 ksi) for C10700-O60 — about 4.4 times as much. Tensile strength is 345 MPa (50 ksi) vs 225 MPa (32.6 ksi).

Which condition does FabDigit quote by default, H04 or O60?

H02 is the default C10700 condition in the FabDigit quote flow (neither H04 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C10700-H04 over C10700-O60?

Pick C10700-H04 when strength drives the design. Pick C10700-O60 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C10700-H04 and C10700-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.