FabDigitFabDigit

Copper Alloy C10700-H03 vs C10700-O60

Copper Alloy · C10700 temper comparison

C10700-H03 and C10700-O60 are two conditions of the same copper alloy grade, C10700: H03 (three-quarter hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C10700-H03 is the stronger of the two: yield strength 280 MPa (40.6 ksi) against 70 MPa (10.2 ksi) for C10700-O60, about 4.0 times as much; tensile strength follows at 315 MPa (45.7 ksi) vs 225 MPa (32.6 ksi). In exchange, C10700-O60 is the more ductile: elongation 45% versus 8% for C10700-H03, and C10700-H03 is harder (85 HB vs 45 HB). C10700-O60 runs hotter in service (300°C vs 250°C continuous).

C10700-H03Choose it when strength drives the design.

C10700-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C10700-H03 vs C10700-O60: properties

C10700-H03C10700-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

315 MPa45.7 ksi
225 MPa32.6 ksi

Yield Strength (0.2% offset)

280 MPa40.6 ksi
70 MPa10.2 ksi

Elongation at Break

8%
45%

Reduction in Area

60%
75%

Shear Strength

195 MPa28.3 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
76 MPa11 ksi

Hardness, Brinell

85 HB
45 HB

Hardness, Rockwell B

47 HRB
40 HRB

Hardness, Vickers

95 HV
50 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

388 W/m·K224 BTU/hr·ft·°F
391 W/m·K226 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
300°C572 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

99.5 % IACS
101 % IACS

Electrical Resistivity

1.72×10⁻⁸ Ω·m0.677 µΩ·in
1.71×10⁻⁸ Ω·m0.672 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

60 / 100
62 / 100

Formability (cold)

70 / 100
98 / 100

Same in both: Machinability 30 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 380 L/kg45.5 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC10700

C10700-H03 vs C10700-O60 — frequently asked

Is C10700-H03 stronger than C10700-O60?

Yes. C10700-H03 has a typical yield strength of 280 MPa (40.6 ksi) against 70 MPa (10.2 ksi) for C10700-O60 — about 4.0 times as much. Tensile strength is 315 MPa (45.7 ksi) vs 225 MPa (32.6 ksi).

Which condition does FabDigit quote by default, H03 or O60?

H02 is the default C10700 condition in the FabDigit quote flow (neither H03 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C10700-H03 over C10700-O60?

Pick C10700-H03 when strength drives the design. Pick C10700-O60 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C10700-H03 and C10700-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.