FabDigitFabDigit

Copper Alloy C10200-H02 vs C10200-O

Copper Alloy · C10200 temper comparison

C10200-H02 and C10200-O are two conditions of the same copper alloy grade, C10200: H02 (half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. C10200-H02 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 69 MPa (10 ksi) for C10200-O, about 3.6 times as much; tensile strength follows at 290 MPa (42.1 ksi) vs 221 MPa (32.1 ksi). In exchange, C10200-O is the more ductile: elongation 45% versus 14% for C10200-H02, and C10200-H02 is harder (80 HB vs 45 HB). C10200-O runs hotter in service (250°C vs 150°C continuous).

C10200-H02Choose it when strength drives the design.

C10200-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C10200-H02 vs C10200-O: properties

C10200-H02C10200-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

290 MPa42.1 ksi
221 MPa32.1 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
69 MPa10 ksi

Elongation at Break

14%
45%

Shear Strength

180 MPa26.1 ksi
152 MPa22 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
76 MPa11 ksi

Hardness, Brinell

80 HB
45 HB

Hardness, Vickers

90 HV
50 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 75%

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

389 W/m·K225 BTU/hr·ft·°F
391 W/m·K226 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
250°C482 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.9 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

100 % IACS
101 % IACS

Electrical Resistivity

1.72×10⁻⁸ Ω·m0.679 µΩ·in
1.71×10⁻⁸ Ω·m0.672 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

20%
18%

Formability (cold)

70 / 100
98 / 100

Same in both: Machinability 22 / 100 · Weldability 65 / 100 · Castability 35 / 100 · Brazeability / Solderability 97 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC10200

C10200-H02 vs C10200-O — frequently asked

Is C10200-H02 stronger than C10200-O?

Yes. C10200-H02 has a typical yield strength of 250 MPa (36.3 ksi) against 69 MPa (10 ksi) for C10200-O — about 3.6 times as much. Tensile strength is 290 MPa (42.1 ksi) vs 221 MPa (32.1 ksi).

Which condition does FabDigit quote by default, H02 or O?

O is the default C10200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C10200-H02 over C10200-O?

Pick C10200-H02 when strength drives the design. Pick C10200-O when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C10200-H02 and C10200-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.