FabDigitFabDigit

YG6 vs YW2

Ceramic · grade comparison

YG6 and YW2 are both ceramic grades. YG6 is the stronger of the two: tensile strength 1,100 MPa (160 ksi) against 1,000 MPa (145 ksi) for YW2, about 10% more. YG6 is the more ductile: elongation 0.2% versus 0% for YW2, and YG6 is harder (1,580 HV vs 1,450 HV). YW2 is lighter (13 g/cm³ vs 14.9 g/cm³ for YG6) and YG6 is stiffer (630 GPa vs 540 GPa).

YG6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

YW2Choose it when weight is the constraint, or when the part sees heat.

YG6 vs YW2: properties

YG6YW2

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

630 GPa91.4 Msi
540 GPa78.3 Msi

Shear Modulus

255 GPa37 Msi
215 GPa31.2 Msi

Bulk Modulus

375 GPa54.4 Msi
330 GPa47.9 Msi

Tensile Strength (Ultimate)

1,100 MPa160 ksi
1,000 MPa145 ksi

Elongation at Break

0.2%
0%

Compressive Strength

4,600 MPa667 ksi
4,300 MPa624 ksi

Flexural Strength

1,800 MPa261 ksi
1,400 MPa203 ksi

Shear Strength

1,200 MPa174 ksi
780 MPa113 ksi

Fracture Toughness (K_IC)

10 MPa·√m9.1 ksi·√in
10.5 MPa·√m9.6 ksi·√in

Hardness, Vickers

1,580 HV
1,450 HV

Hardness, Knoop

1,500 HK
1,420 HK

Same in both: Poisson's Ratio 0.22 · Hardness, Mohs 9

Physical

Density and transition temperatures.

Density

14.9 g/cm³0.54 lb/in³
13 g/cm³0.47 lb/in³

Same in both: Melting Point (Solidus) 1,320°C2,408 °F · Porosity 0.02%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

80 W/m·K46.2 BTU/hr·ft·°F
30 W/m·K17.3 BTU/hr·ft·°F

Specific Heat Capacity

220 J/kg·K0.05 BTU/lb·°F
250 J/kg·K0.06 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

4.5 µm/m·K2.5 µin/in·°F
6.2 µm/m·K3.4 µin/in·°F

Max Service Temperature (continuous)

600°C1,112 °F
900°C1,652 °F

Same in both: Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

2×10⁻⁷ Ω·m7.87 µΩ·in
3.5×10⁻⁷ Ω·m13.8 µΩ·in

Volume Resistivity

2×10⁻⁵ Ω·cm
3.5×10⁻⁵ Ω·cm

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
50 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Polishability

90 / 100
85 / 100

Sintering / Firing Temperature

1,420°C2,588 °F
1,430°C2,606 °F

Same in both: Machinability 5 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

330 MJ/kg141,875 BTU/lb
400 MJ/kg171,969 BTU/lb

Embodied Carbon (primary production)

24 kg CO₂/kg
30 kg CO₂/kg

Embodied Water

400 L/kg47.9 gal/lb
300 L/kg35.9 gal/lb

Typical Recycled Content

30%
25%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

74 kN·m/kg
77 kN·m/kg

Specific Stiffness (E / density)

42.3 MN·m/kg
41.5 MN·m/kg

Thermal Diffusivity

24.4 mm²/s
9.2 mm²/s

Thermal Shock Resistance Index

31
9

Strength versus weight

Yield strength against density for every ceramic grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,000234567Density (g/cm³)Yield strength (MPa) — log scale

Manufacturing and finishing

CapabilityYG6YW2
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

YG6 vs YW2 — frequently asked

Is YG6 stronger than YW2?

Yes. YG6 has a typical tensile strength of 1,100 MPa (160 ksi) against 1,000 MPa (145 ksi) for YW2 — about 10% more.

Which is cheaper, YG6 or YW2?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

When should I choose YG6 over YW2?

Pick YG6 when strength drives the design, or when the part is bent, formed or impact-loaded. Pick YW2 when weight is the constraint, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in YG6 and YW2 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.