FabDigitFabDigit

Aluminum ZL207-F vs ZL207-T1

Aluminum · ZL207 temper comparison

ZL207-F and ZL207-T1 are two conditions of the same aluminum grade, ZL207: F (as fabricated) versus T1 (cooled from hot working and naturally aged). The chemistry is identical, so every difference below comes from the condition. ZL207-T1 is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 120 MPa (17.4 ksi) for ZL207-F, about 25% more; tensile strength follows at 185 MPa (26.8 ksi) vs 155 MPa (22.5 ksi). In exchange, ZL207-F is the more ductile: elongation 2% versus 1.5% for ZL207-T1, and ZL207-T1 is harder (80 HB vs 70 HB). ZL207-T1 runs hotter in service (350°C vs 300°C continuous).

ZL207-FChoose it when the part is bent, formed or impact-loaded.

ZL207-T1Choose it when strength drives the design, or when the part sees heat.

ZL207-F vs ZL207-T1: properties

ZL207-FZL207-T1

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

155 MPa22.5 ksi
185 MPa26.8 ksi

Yield Strength (0.2% offset)

120 MPa17.4 ksi
150 MPa21.8 ksi

Elongation at Break

2%
1.5%

Shear Strength

110 MPa16 ksi
130 MPa18.9 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
70 MPa10.2 ksi

Hardness, Brinell

70 HB
80 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.85 g/cm³0.1 lb/in³ · Melting Point (Solidus) 545°C1,013 °F · Liquidus Temperature 640°C1,184 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

125 W/m·K72.2 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
350°C662 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

30 % IACS
32 % IACS

Electrical Resistivity

5.75×10⁻⁸ Ω·m2.26 µΩ·in
5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

32 / 100
33 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.72 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

90%
100%

Same in both: Weldability 25 / 100 · Formability (cold) 5 / 100 · Castability 50 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleZL207

ZL207-F vs ZL207-T1 — frequently asked

Is ZL207-T1 stronger than ZL207-F?

Yes. ZL207-T1 has a typical yield strength of 150 MPa (21.8 ksi) against 120 MPa (17.4 ksi) for ZL207-F — about 25% more. Tensile strength is 185 MPa (26.8 ksi) vs 155 MPa (22.5 ksi).

Which condition does FabDigit quote by default, F or T1?

T1 is the default ZL207 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ZL207-F over ZL207-T1?

Pick ZL207-F when the part is bent, formed or impact-loaded. Pick ZL207-T1 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZL207-F and ZL207-T1 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.