FabDigitFabDigit

Aluminum ZL101-T4 vs ZL101-T6

Aluminum · ZL101 temper comparison

ZL101-T4 and ZL101-T6 are two conditions of the same aluminum grade, ZL101: T4 (solution heat treated and naturally aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. ZL101-T6 is the stronger of the two: yield strength 200 MPa (29 ksi) against 115 MPa (16.7 ksi) for ZL101-T4, about 74% more; tensile strength follows at 265 MPa (38.4 ksi) vs 210 MPa (30.5 ksi). In exchange, ZL101-T4 is the more ductile: elongation 8% versus 5% for ZL101-T6, and ZL101-T6 is harder (80 HB vs 55 HB). ZL101-T6 runs hotter in service (150°C vs 100°C continuous).

ZL101-T4Choose it when the part is bent, formed or impact-loaded.

ZL101-T6Choose it when strength drives the design, or when the part sees heat.

ZL101-T4 vs ZL101-T6: properties

ZL101-T4ZL101-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

210 MPa30.5 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

115 MPa16.7 ksi
200 MPa29 ksi

Elongation at Break

8%
5%

Shear Strength

150 MPa21.8 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
90 MPa13.1 ksi

Charpy V-Notch Impact (RT)

7 J5.2 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

55 HB
80 HB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 22 MPa·√m20 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 615°C1,139 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

145 W/m·K83.8 BTU/hr·ft·°F
151 W/m·K87.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

36 % IACS
39 % IACS

Same in both: Electrical Resistivity 4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
72 / 100

Same in both: Weldability 75 / 100 · Castability 92 / 100 · Brazeability / Solderability 35 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 195 MJ/kg83,835 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleZL101

ZL101-T4 vs ZL101-T6 — frequently asked

Is ZL101-T6 stronger than ZL101-T4?

Yes. ZL101-T6 has a typical yield strength of 200 MPa (29 ksi) against 115 MPa (16.7 ksi) for ZL101-T4 — about 74% more. Tensile strength is 265 MPa (38.4 ksi) vs 210 MPa (30.5 ksi).

Which condition does FabDigit quote by default, T4 or T6?

T6 is the default ZL101 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ZL101-T4 or ZL101-T6?

ZL101-T6. Its machinability rates very good (72/100) against good (65/100) for ZL101-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZL101-T4 and ZL101-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.