ZL101-T2 and ZL101-T6 are two conditions of the same aluminum grade, ZL101: T2 (cooled from hot working, cold worked and naturally aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. ZL101-T6 is the stronger of the two: yield strength 200 MPa (29 ksi) against 80 MPa (11.6 ksi) for ZL101-T2, about 150% more; tensile strength follows at 265 MPa (38.4 ksi) vs 150 MPa (21.8 ksi). ZL101-T6 is the more ductile: elongation 5% versus 4% for ZL101-T2, and ZL101-T6 is harder (80 HB vs 47 HB). ZL101-T2 runs hotter in service (250°C vs 150°C continuous) and ZL101-T2 conducts heat better (170 W/m·K vs 151 W/m·K). On the shop floor, ZL101-T6 machines more easily (very good vs good).

ZL101-T2Choose it when the part sees heat.

ZL101-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

ZL101-T2 vs ZL101-T6: properties

ZL101-T2ZL101-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

71 GPa10.3 Msi
72 GPa10.4 Msi

Tensile Strength (Ultimate)

150 MPa21.8 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

80 MPa11.6 ksi
200 MPa29 ksi

Elongation at Break

4%
5%

Shear Strength

105 MPa15.2 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
90 MPa13.1 ksi

Fracture Toughness (K_IC)

26 MPa·√m23.7 ksi·√in
22 MPa·√m20 ksi·√in

Charpy V-Notch Impact (RT)

7 J5.2 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

47 HB
80 HB

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 615°C1,139 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

170 W/m·K98.2 BTU/hr·ft·°F
151 W/m·K87.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
150°C302 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

43 % IACS
39 % IACS

Electrical Resistivity

4×10⁻⁸ Ω·m1.57 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
72 / 100

Weldability

78 / 100
75 / 100

Same in both: Castability 92 / 100 · Brazeability / Solderability 35 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 195 MJ/kg83,835 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleZL101

ZL101-T2 vs ZL101-T6 — frequently asked

Is ZL101-T6 stronger than ZL101-T2?

Yes. ZL101-T6 has a typical yield strength of 200 MPa (29 ksi) against 80 MPa (11.6 ksi) for ZL101-T2 — about 150% more. Tensile strength is 265 MPa (38.4 ksi) vs 150 MPa (21.8 ksi).

Which condition does FabDigit quote by default, T2 or T6?

T6 is the default ZL101 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ZL101-T2 or ZL101-T6?

ZL101-T6. Its machinability rates very good (72/100) against good (55/100) for ZL101-T2.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZL101-T2 and ZL101-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.