FabDigitFabDigit

Aluminum V95-T1 vs V95-T2

Aluminum · V95 temper comparison

V95-T1 and V95-T2 are two conditions of the same aluminum grade, V95: T1 (cooled from hot working and naturally aged) versus T2 (cooled from hot working, cold worked and naturally aged). The chemistry is identical, so every difference below comes from the condition. V95-T1 is the stronger of the two: yield strength 470 MPa (68.2 ksi) against 400 MPa (58 ksi) for V95-T2, about 18% more; tensile strength follows at 545 MPa (79 ksi) vs 480 MPa (69.6 ksi). In exchange, V95-T2 is the more ductile: elongation 10% versus 8% for V95-T1, and V95-T1 is harder (150 HB vs 135 HB). V95-T2 runs hotter in service (150°C vs 120°C continuous) and V95-T2 conducts heat better (155 W/m·K vs 130 W/m·K).

V95-T1Choose it when strength drives the design.

V95-T2Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

V95-T1 vs V95-T2: properties

V95-T1V95-T2

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

545 MPa79 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

470 MPa68.2 ksi
400 MPa58 ksi

Elongation at Break

8%
10%

Shear Strength

330 MPa47.9 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
150 MPa21.8 ksi

Fracture Toughness (K_IC)

26 MPa·√m23.7 ksi·√in
33 MPa·√m30 ksi·√in

Hardness, Brinell

150 HB
135 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Reduction in Area 25% · Compressive Strength 480 MPa69.6 ksi · Hardness, Rockwell B 87 HRB · Hardness, Vickers 160 HV

Physical

Density and transition temperatures.

Same in both: Density 2.85 g/cm³0.1 lb/in³ · Melting Point (Solidus) 477°C891 °F · Liquidus Temperature 635°C1,175 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

130 W/m·K75.1 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

33 % IACS
40 % IACS

Same in both: Electrical Resistivity 5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

35 / 100
48 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

75 / 100
72 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 20 / 100 · Formability (cold) 25 / 100 · Castability 20 / 100 · Brazeability / Solderability 15 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 210 MJ/kg90,284 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleV95

V95-T1 vs V95-T2 — frequently asked

Is V95-T1 stronger than V95-T2?

Yes. V95-T1 has a typical yield strength of 470 MPa (68.2 ksi) against 400 MPa (58 ksi) for V95-T2 — about 18% more. Tensile strength is 545 MPa (79 ksi) vs 480 MPa (69.6 ksi).

Which condition does FabDigit quote by default, T1 or T2?

T1 is the default V95 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose V95-T1 over V95-T2?

Pick V95-T1 when strength drives the design. Pick V95-T2 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in V95-T1 and V95-T2 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.