FabDigitFabDigit

Aluminum EN AC-46400-F vs EN AC-46400-T5

Aluminum · EN AC-46400 temper comparison

EN AC-46400-F and EN AC-46400-T5 are two conditions of the same aluminum grade, EN AC-46400: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-46400-T5 is the stronger of the two: yield strength 170 MPa (24.7 ksi) against 95 MPa (13.8 ksi) for EN AC-46400-F, about 79% more; tensile strength follows at 215 MPa (31.2 ksi) vs 165 MPa (23.9 ksi). In exchange, EN AC-46400-F is the more ductile: elongation 1.5% versus 1% for EN AC-46400-T5, and EN AC-46400-T5 is harder (90 HB vs 65 HB).

EN AC-46400-FChoose it when the part is bent, formed or impact-loaded.

EN AC-46400-T5Choose it when strength drives the design.

EN AC-46400-F vs EN AC-46400-T5: properties

EN AC-46400-FEN AC-46400-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

165 MPa23.9 ksi
215 MPa31.2 ksi

Yield Strength (0.2% offset)

95 MPa13.8 ksi
170 MPa24.7 ksi

Elongation at Break

1.5%
1%

Shear Strength

115 MPa16.7 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

65 MPa9.4 ksi
85 MPa12.3 ksi

Fracture Toughness (K_IC)

15 MPa·√m13.7 ksi·√in
16 MPa·√m14.6 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
3 J1.8 ft·lbf

Hardness, Brinell

65 HB
90 HB

Hardness, Vickers

70 HV
95 HV

Same in both: Elastic (Young's) Modulus 75 GPa10.9 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 170 MPa24.7 ksi

Physical

Density and transition temperatures.

Same in both: Density 2.75 g/cm³0.1 lb/in³ · Melting Point (Solidus) 520°C968 °F · Liquidus Temperature 595°C1,103 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
160°C320 °F

Same in both: Thermal Conductivity 125 W/m·K72.2 BTU/hr·ft·°F · Specific Heat Capacity 960 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
31 % IACS

Electrical Resistivity

6.2×10⁻⁸ Ω·m2.44 µΩ·in
5.6×10⁻⁸ Ω·m2.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
46 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
70%

Weldability

40 / 100
35 / 100

Formability (cold)

10 / 100
5 / 100

Same in both: Castability 88 / 100 · Brazeability / Solderability 25 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 150 MJ/kg64,488 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-46400

EN AC-46400-F vs EN AC-46400-T5 — frequently asked

Is EN AC-46400-T5 stronger than EN AC-46400-F?

Yes. EN AC-46400-T5 has a typical yield strength of 170 MPa (24.7 ksi) against 95 MPa (13.8 ksi) for EN AC-46400-F — about 79% more. Tensile strength is 215 MPa (31.2 ksi) vs 165 MPa (23.9 ksi).

Which condition does FabDigit quote by default, F or T5?

F is the default EN AC-46400 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-46400-F or EN AC-46400-T5?

EN AC-46400-F, by a small margin. Both rate good for machinability — 65/100 against 60/100 for EN AC-46400-T5; for welding the order is EN AC-46400-F first (fair, 40/100) then EN AC-46400-T5 (fair, 35/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-46400-F and EN AC-46400-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.