FabDigitFabDigit

Aluminum EN AC-46000 F-S vs EN AC-46000-T5

Aluminum · EN AC-46000 temper comparison

EN AC-46000 F-S and EN AC-46000-T5 are two conditions of the same aluminum grade, EN AC-46000: F-S (f) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-46000-T5 is the stronger of the two: yield strength 190 MPa (27.6 ksi) against 95 MPa (13.8 ksi) for EN AC-46000 F-S, about 100% more; tensile strength follows at 275 MPa (39.9 ksi) vs 150 MPa (21.8 ksi). EN AC-46000-T5 is harder — 95 HB against 60 HB for EN AC-46000 F-S — which matters for wear surfaces and threads. EN AC-46000-T5 is stiffer (75 GPa vs 70 GPa) and EN AC-46000-T5 runs hotter in service (170°C vs 150°C continuous). On the shop floor, EN AC-46000 F-S welds better (fair vs poor).

EN AC-46000 F-SChoose it when it will be welded.

EN AC-46000-T5Choose it when strength drives the design, or when surface hardness matters.

EN AC-46000 F-S vs EN AC-46000-T5: properties

EN AC-46000 F-SEN AC-46000-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

70 GPa10.2 Msi
75 GPa10.9 Msi

Tensile Strength (Ultimate)

150 MPa21.8 ksi
275 MPa39.9 ksi

Yield Strength (0.2% offset)

95 MPa13.8 ksi
190 MPa27.6 ksi

Shear Strength

100 MPa14.5 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
140 MPa20.3 ksi

Fracture Toughness (K_IC)

13 MPa·√m11.8 ksi·√in
16 MPa·√m14.6 ksi·√in

Charpy V-Notch Impact (RT)

2 J1.5 ft·lbf
3 J1.8 ft·lbf

Hardness, Brinell

60 HB
95 HB

Hardness, Rockwell B

20 HRB
55 HRB

Hardness, Vickers

63 HV
100 HV

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 74 GPa10.7 Msi · Poisson's Ratio 0.33 · Elongation at Break 1%

Physical

Density and transition temperatures.

Same in both: Density 2.75 g/cm³0.1 lb/in³ · Melting Point (Solidus) 515°C959 °F · Liquidus Temperature 595°C1,103 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

96 W/m·K55.5 BTU/hr·ft·°F
110 W/m·K63.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
170°C338 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

22 % IACS
25 % IACS

Electrical Resistivity

7.8×10⁻⁸ Ω·m3.07 µΩ·in
6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

40 / 100
42 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
72%

Weldability

35 / 100
25 / 100

Formability (cold)

5 / 100
6 / 100

Same in both: Castability 95 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 90%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-46000

EN AC-46000 F-S vs EN AC-46000-T5 — frequently asked

Is EN AC-46000-T5 stronger than EN AC-46000 F-S?

Yes. EN AC-46000-T5 has a typical yield strength of 190 MPa (27.6 ksi) against 95 MPa (13.8 ksi) for EN AC-46000 F-S — about 100% more. Tensile strength is 275 MPa (39.9 ksi) vs 150 MPa (21.8 ksi).

Which condition does FabDigit quote by default, F-S or T5?

F-D is the default EN AC-46000 condition in the FabDigit quote flow (neither F-S nor T5). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, EN AC-46000 F-S or EN AC-46000-T5?

EN AC-46000 F-S. Its weldability rates fair (35/100) against poor (25/100) for EN AC-46000-T5.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-46000 F-S and EN AC-46000-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.