FabDigitFabDigit

Aluminum EN AC-43500-T4 vs EN AC-43500-T5

Aluminum · EN AC-43500 temper comparison

EN AC-43500-T4 and EN AC-43500-T5 are two conditions of the same aluminum grade, EN AC-43500: T4 (solution heat treated and naturally aged) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-43500-T5 is the stronger of the two: yield strength 180 MPa (26.1 ksi) against 115 MPa (16.7 ksi) for EN AC-43500-T4, about 57% more. In exchange, EN AC-43500-T4 is the more ductile: elongation 18% versus 6% for EN AC-43500-T5, and EN AC-43500-T5 is harder (95 HB vs 68 HB). EN AC-43500-T5 runs hotter in service (175°C vs 100°C continuous) and EN AC-43500-T5 conducts heat better (150 W/m·K vs 130 W/m·K).

EN AC-43500-T4Choose it when the part is bent, formed or impact-loaded.

EN AC-43500-T5Choose it when strength drives the design, or when the part sees heat.

EN AC-43500-T4 vs EN AC-43500-T5: properties

EN AC-43500-T4EN AC-43500-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

265 MPa38.4 ksi
275 MPa39.9 ksi

Yield Strength (0.2% offset)

115 MPa16.7 ksi
180 MPa26.1 ksi

Elongation at Break

18%
6%

Compressive Strength

120 MPa17.4 ksi
140 MPa20.3 ksi

Shear Strength

170 MPa24.7 ksi
185 MPa26.8 ksi

Fatigue Strength (Endurance Limit)

75 MPa10.9 ksi
90 MPa13.1 ksi

Fracture Toughness (K_IC)

28 MPa·√m25.5 ksi·√in
22 MPa·√m20 ksi·√in

Charpy V-Notch Impact (RT)

9 J6.6 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

68 HB
95 HB

Same in both: Elastic (Young's) Modulus 75 GPa10.9 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

130 W/m·K75.1 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
175°C347 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

22 % IACS
28 % IACS

Electrical Resistivity

7.8×10⁻⁸ Ω·m3.07 µΩ·in
6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.79 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
72%

Formability (cold)

40 / 100
28 / 100

Same in both: Weldability 70 / 100 · Castability 95 / 100 · Brazeability / Solderability 30 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 10.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-43500

EN AC-43500-T4 vs EN AC-43500-T5 — frequently asked

Is EN AC-43500-T5 stronger than EN AC-43500-T4?

Yes. EN AC-43500-T5 has a typical yield strength of 180 MPa (26.1 ksi) against 115 MPa (16.7 ksi) for EN AC-43500-T4 — about 57% more. Tensile strength is 275 MPa (39.9 ksi) vs 265 MPa (38.4 ksi).

Which condition does FabDigit quote by default, T4 or T5?

F is the default EN AC-43500 condition in the FabDigit quote flow (neither T4 nor T5). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-43500-T4 or EN AC-43500-T5?

EN AC-43500-T5, by a small margin. Both rate good for machinability — 65/100 against 58/100 for EN AC-43500-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-43500-T4 and EN AC-43500-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.