Aluminum EN AC-43500-F vs EN AC-43500-T5

Aluminum · EN AC-43500 temper comparison

EN AC-43500-F and EN AC-43500-T5 are two conditions of the same aluminum grade, EN AC-43500: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-43500-T5 is the stronger of the two: yield strength 180 MPa (26.1 ksi) against 135 MPa (19.6 ksi) for EN AC-43500-F, about 33% more. In exchange, EN AC-43500-F is the more ductile: elongation 8% versus 6% for EN AC-43500-T5, and EN AC-43500-T5 is harder (95 HB vs 85 HB). EN AC-43500-T5 runs hotter in service (175°C vs 150°C continuous) and EN AC-43500-T5 conducts electricity better (28 % IACS vs 25 % IACS).

EN AC-43500-FChoose it when the part is bent, formed or impact-loaded.

EN AC-43500-T5Choose it when strength drives the design, or when the part sees heat.

EN AC-43500-F vs EN AC-43500-T5: properties

EN AC-43500-FEN AC-43500-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

270 MPa39.2 ksi
275 MPa39.9 ksi

Yield Strength (0.2% offset)

135 MPa19.6 ksi
180 MPa26.1 ksi

Elongation at Break

8%
6%

Shear Strength

175 MPa25.4 ksi
185 MPa26.8 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
90 MPa13.1 ksi

Charpy V-Notch Impact (RT)

5 J3.7 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

85 HB
95 HB

Same in both: Elastic (Young's) Modulus 75 GPa10.9 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33 · Compressive Strength 140 MPa20.3 ksi · Fracture Toughness (K_IC) 22 MPa·√m20 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

140 W/m·K80.9 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
28 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.79 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
72%

Weldability

72 / 100
70 / 100

Formability (cold)

35 / 100
28 / 100

Same in both: Castability 95 / 100 · Brazeability / Solderability 30 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 10.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-43500

EN AC-43500-F vs EN AC-43500-T5 — frequently asked

Is EN AC-43500-T5 stronger than EN AC-43500-F?

Yes. EN AC-43500-T5 has a typical yield strength of 180 MPa (26.1 ksi) against 135 MPa (19.6 ksi) for EN AC-43500-F — about 33% more. Tensile strength is 275 MPa (39.9 ksi) vs 270 MPa (39.2 ksi).

Which condition does FabDigit quote by default, F or T5?

F is the default EN AC-43500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-43500-F over EN AC-43500-T5?

Pick EN AC-43500-F when the part is bent, formed or impact-loaded. Pick EN AC-43500-T5 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-43500-F and EN AC-43500-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.