FabDigitFabDigit

Aluminum EN AC-43400-F vs EN AC-43400-T6

Aluminum · EN AC-43400 temper comparison

EN AC-43400-F and EN AC-43400-T6 are two conditions of the same aluminum grade, EN AC-43400: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-43400-T6 is the stronger of the two: yield strength 230 MPa (33.4 ksi) against 155 MPa (22.5 ksi) for EN AC-43400-F, about 48% more; tensile strength follows at 310 MPa (45 ksi) vs 260 MPa (37.7 ksi). EN AC-43400-T6 is the more ductile: elongation 3% versus 2% for EN AC-43400-F, and EN AC-43400-T6 is harder (95 HB vs 75 HB). EN AC-43400-T6 conducts heat better (145 W/m·K vs 130 W/m·K).

EN AC-43400-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-43400-F vs EN AC-43400-T6: properties

EN AC-43400-FEN AC-43400-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

260 MPa37.7 ksi
310 MPa45 ksi

Yield Strength (0.2% offset)

155 MPa22.5 ksi
230 MPa33.4 ksi

Elongation at Break

2%
3%

Compressive Strength

160 MPa23.2 ksi
235 MPa34.1 ksi

Shear Strength

175 MPa25.4 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
100 MPa14.5 ksi

Fracture Toughness (K_IC)

17 MPa·√m15.5 ksi·√in
18 MPa·√m16.4 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

75 HB
95 HB

Hardness, Vickers

85 HV
107 HV

Same in both: Elastic (Young's) Modulus 73 GPa10.6 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

130 W/m·K75.1 BTU/hr·ft·°F
145 W/m·K83.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 490 J/g211 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

27 % IACS
30 % IACS

Electrical Resistivity

6.4×10⁻⁸ Ω·m2.52 µΩ·in
5.75×10⁻⁸ Ω·m2.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
52 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
70 / 100

Weldability

35 / 100
30 / 100

Same in both: Castability 95 / 100 · Brazeability / Solderability 30 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-43400

EN AC-43400-F vs EN AC-43400-T6 — frequently asked

Is EN AC-43400-T6 stronger than EN AC-43400-F?

Yes. EN AC-43400-T6 has a typical yield strength of 230 MPa (33.4 ksi) against 155 MPa (22.5 ksi) for EN AC-43400-F — about 48% more. Tensile strength is 310 MPa (45 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, F or T6?

F is the default EN AC-43400 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-43400-F or EN AC-43400-T6?

EN AC-43400-T6. Its machinability rates very good (70/100) against good (65/100) for EN AC-43400-F; for welding the order is EN AC-43400-F first (fair, 35/100) then EN AC-43400-T6 (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-43400-F and EN AC-43400-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.