FabDigitFabDigit

Aluminum ADC6 HVDC-F vs ADC6-O

Aluminum · ADC6 temper comparison

ADC6 HVDC-F and ADC6-O are two conditions of the same aluminum grade, ADC6: HVDC-F (vacuum-assisted high-pressure die cast, as-cast) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. ADC6 HVDC-F is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 120 MPa (17.4 ksi) for ADC6-O, about 25% more; tensile strength follows at 280 MPa (40.6 ksi) vs 235 MPa (34.1 ksi). ADC6 HVDC-F is the more ductile: elongation 13% versus 11% for ADC6-O, and ADC6 HVDC-F is harder (66 HB vs 58 HB). On the shop floor, ADC6 HVDC-F welds better (good vs fair).

ADC6 HVDC-FChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

ADC6 HVDC-F vs ADC6-O: properties

ADC6 HVDC-FADC6-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

280 MPa40.6 ksi
235 MPa34.1 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
120 MPa17.4 ksi

Elongation at Break

13%
11%

Compressive Strength

155 MPa22.5 ksi
125 MPa18.1 ksi

Shear Strength

180 MPa26.1 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
85 MPa12.3 ksi

Charpy V-Notch Impact (RT)

13 J9.6 ft·lbf
11 J8.1 ft·lbf

Hardness, Brinell

66 HB
58 HB

Hardness, Vickers

71 HV
62 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.63 g/cm³0.1 lb/in³ · Melting Point (Solidus) 590°C1,094 °F · Liquidus Temperature 630°C1,166 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 130 W/m·K75.1 BTU/hr·ft·°F · Specific Heat Capacity 960 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24.5 µm/m·K13.6 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

67 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

200%
190%

Weldability

60 / 100
48 / 100

Formability (cold)

18 / 100
20 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleADC6

ADC6 HVDC-F vs ADC6-O — frequently asked

Is ADC6 HVDC-F stronger than ADC6-O?

Yes. ADC6 HVDC-F has a typical yield strength of 150 MPa (21.8 ksi) against 120 MPa (17.4 ksi) for ADC6-O — about 25% more. Tensile strength is 280 MPa (40.6 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, HVDC-F or O?

F is the default ADC6 condition in the FabDigit quote flow (neither HVDC-F nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ADC6 HVDC-F or ADC6-O?

ADC6 HVDC-F, by a small margin. Both rate good for machinability — 67/100 against 62/100 for ADC6-O; for welding the order is ADC6 HVDC-F first (good, 60/100) then ADC6-O (fair, 48/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in ADC6 HVDC-F and ADC6-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.