FabDigitFabDigit

Aluminum ADC1-F vs ADC1-T5

Aluminum · ADC1 temper comparison

ADC1-F and ADC1-T5 are two conditions of the same aluminum grade, ADC1: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. ADC1-T5 is the stronger of the two: yield strength 160 MPa (23.2 ksi) against 145 MPa (21 ksi) for ADC1-F, about 10% more. In exchange, ADC1-F is the more ductile: elongation 2.5% versus 2% for ADC1-T5, and ADC1-T5 is harder (80 HB vs 75 HB). ADC1-T5 runs hotter in service (175°C vs 150°C continuous).

ADC1-FChoose it when the part is bent, formed or impact-loaded.

ADC1-T5Choose it when strength drives the design, or when the part sees heat.

ADC1-F vs ADC1-T5: properties

ADC1-FADC1-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

280 MPa40.6 ksi
285 MPa41.3 ksi

Yield Strength (0.2% offset)

145 MPa21 ksi
160 MPa23.2 ksi

Elongation at Break

2.5%
2%

Shear Strength

170 MPa24.7 ksi
175 MPa25.4 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
135 MPa19.6 ksi

Fracture Toughness (K_IC)

15 MPa·√m13.7 ksi·√in
14 MPa·√m12.7 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
3 J1.8 ft·lbf

Hardness, Brinell

75 HB
80 HB

Hardness, Vickers

80 HV
85 HV

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 574°C1,065 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

121 W/m·K69.9 BTU/hr·ft·°F
128 W/m·K74 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.4 µm/m·K11.3 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

31 % IACS
34 % IACS

Electrical Resistivity

5.6×10⁻⁸ Ω·m2.2 µΩ·in
5.1×10⁻⁸ Ω·m2.01 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
37 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
47%

Formability (cold)

5 / 100
4 / 100

Same in both: Weldability 35 / 100 · Castability 95 / 100 · Brazeability / Solderability 30 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 195 MJ/kg83,835 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleADC1

ADC1-F vs ADC1-T5 — frequently asked

Is ADC1-T5 stronger than ADC1-F?

Yes. ADC1-T5 has a typical yield strength of 160 MPa (23.2 ksi) against 145 MPa (21 ksi) for ADC1-F — about 10% more. Tensile strength is 285 MPa (41.3 ksi) vs 280 MPa (40.6 ksi).

Which condition does FabDigit quote by default, F or T5?

F is the default ADC1 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ADC1-F over ADC1-T5?

Pick ADC1-F when the part is bent, formed or impact-loaded. Pick ADC1-T5 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ADC1-F and ADC1-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.