FabDigitFabDigit

Aluminum A390-T6 vs A390-T7

Aluminum · A390 temper comparison

A390-T6 and A390-T7 are two conditions of the same aluminum grade, A390: T6 (solution heat treated and artificially aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. A390-T6 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 240 MPa (34.8 ksi) for A390-T7, about 15% more; tensile strength follows at 285 MPa (41.3 ksi) vs 250 MPa (36.3 ksi). In exchange, A390-T7 is the more ductile: elongation 1% versus 0.8% for A390-T6, and A390-T6 is harder (145 HB vs 125 HB). A390-T7 runs hotter in service (230°C vs 175°C continuous).

A390-T6Choose it when strength drives the design.

A390-T7Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

A390-T6 vs A390-T7: properties

A390-T6A390-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

285 MPa41.3 ksi
250 MPa36.3 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
240 MPa34.8 ksi

Elongation at Break

0.8%
1%

Compressive Strength

300 MPa43.5 ksi
310 MPa45 ksi

Shear Strength

215 MPa31.2 ksi
170 MPa24.7 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
105 MPa15.2 ksi

Hardness, Brinell

145 HB
125 HB

Hardness, Vickers

125 HV
131 HV

Same in both: Elastic (Young's) Modulus 81 GPa11.7 Msi · Shear Modulus 30.5 GPa4.4 Msi · Bulk Modulus 79 GPa11.5 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 12 MPa·√m10.9 ksi·√in · Charpy V-Notch Impact (RT) 2 J1.5 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 507°C945 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

134 W/m·K77.4 BTU/hr·ft·°F
142 W/m·K82 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
230°C446 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 460 J/g198 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

27 % IACS
28 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

42 / 100
45 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
31 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
42%

Same in both: Weldability 20 / 100 · Formability (cold) 3 / 100 · Castability 80 / 100 · Brazeability / Solderability 15 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleA390

A390-T6 vs A390-T7 — frequently asked

Is A390-T6 stronger than A390-T7?

Yes. A390-T6 has a typical yield strength of 275 MPa (39.9 ksi) against 240 MPa (34.8 ksi) for A390-T7 — about 15% more. Tensile strength is 285 MPa (41.3 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, T6 or T7?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose A390-T6 over A390-T7?

Pick A390-T6 when strength drives the design. Pick A390-T7 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A390-T6 and A390-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.