FabDigitFabDigit

Aluminum 8030-H14 vs 8030-H16

Aluminum · 8030 temper comparison

8030-H14 and 8030-H16 are two conditions of the same aluminum grade, 8030: H14 (strain hardened, half hard) versus H16 (strain hardened, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. 8030-H16 is the stronger of the two: yield strength 128 MPa (18.6 ksi) against 105 MPa (15.2 ksi) for 8030-H14, about 22% more; tensile strength follows at 148 MPa (21.5 ksi) vs 128 MPa (18.6 ksi). In exchange, 8030-H14 is the more ductile: elongation 8% versus 5% for 8030-H16, and 8030-H16 is harder (40 HB vs 35 HB). 8030-H14 runs hotter in service (120°C vs 110°C continuous).

8030-H14Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

8030-H16Choose it when strength drives the design.

8030-H14 vs 8030-H16: properties

8030-H148030-H16

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

128 MPa18.6 ksi
148 MPa21.5 ksi

Yield Strength (0.2% offset)

105 MPa15.2 ksi
128 MPa18.6 ksi

Elongation at Break

8%
5%

Reduction in Area

50%
40%

Shear Strength

80 MPa11.6 ksi
90 MPa13.1 ksi

Fatigue Strength (Endurance Limit)

45 MPa6.5 ksi
48 MPa7 ksi

Hardness, Brinell

35 HB
40 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

227 W/m·K131 BTU/hr·ft·°F
226 W/m·K131 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
110°C230 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61.3 % IACS
61.1 % IACS

Electrical Resistivity

2.81×10⁻⁸ Ω·m1.11 µΩ·in
2.82×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

36 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

36%
40%

Weldability

82 / 100
80 / 100

Formability (cold)

80 / 100
70 / 100

Same in both: Castability 60 / 100 · Brazeability / Solderability 70 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale8030

8030-H14 vs 8030-H16 — frequently asked

Is 8030-H16 stronger than 8030-H14?

Yes. 8030-H16 has a typical yield strength of 128 MPa (18.6 ksi) against 105 MPa (15.2 ksi) for 8030-H14 — about 22% more. Tensile strength is 148 MPa (21.5 ksi) vs 128 MPa (18.6 ksi).

Which condition does FabDigit quote by default, H14 or H16?

O is the default 8030 condition in the FabDigit quote flow (neither H14 nor H16). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 8030-H14 over 8030-H16?

Pick 8030-H14 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 8030-H16 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8030-H14 and 8030-H16 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.