FabDigitFabDigit

Aluminum 8017-H14 vs 8017-H16

Aluminum · 8017 temper comparison

8017-H14 and 8017-H16 are two conditions of the same aluminum grade, 8017: H14 (strain hardened, half hard) versus H16 (strain hardened, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. 8017-H16 is the stronger of the two: yield strength 130 MPa (18.9 ksi) against 115 MPa (16.7 ksi) for 8017-H14, about 13% more; tensile strength follows at 145 MPa (21 ksi) vs 130 MPa (18.9 ksi). In exchange, 8017-H14 is the more ductile: elongation 9% versus 6% for 8017-H16, and 8017-H16 is harder (42 HB vs 37 HB). 8017-H14 runs hotter in service (120°C vs 110°C continuous).

8017-H14Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

8017-H16Choose it when strength drives the design.

8017-H14 vs 8017-H16: properties

8017-H148017-H16

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

130 MPa18.9 ksi
145 MPa21 ksi

Yield Strength (0.2% offset)

115 MPa16.7 ksi
130 MPa18.9 ksi

Elongation at Break

9%
6%

Shear Strength

82 MPa11.9 ksi
90 MPa13.1 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
55 MPa8 ksi

Hardness, Brinell

37 HB
42 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

230 W/m·K133 BTU/hr·ft·°F
229 W/m·K132 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
110°C230 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

60.8 % IACS
60.5 % IACS

Electrical Resistivity

2.84×10⁻⁸ Ω·m1.12 µΩ·in
2.85×10⁻⁸ Ω·m1.12 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
57 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
35%

Weldability

85 / 100
84 / 100

Formability (cold)

85 / 100
75 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale8017

8017-H14 vs 8017-H16 — frequently asked

Is 8017-H16 stronger than 8017-H14?

Yes. 8017-H16 has a typical yield strength of 130 MPa (18.9 ksi) against 115 MPa (16.7 ksi) for 8017-H14 — about 13% more. Tensile strength is 145 MPa (21 ksi) vs 130 MPa (18.9 ksi).

Which condition does FabDigit quote by default, H14 or H16?

H12 is the default 8017 condition in the FabDigit quote flow (neither H14 nor H16). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 8017-H14 over 8017-H16?

Pick 8017-H14 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 8017-H16 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8017-H14 and 8017-H16 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.