8014-H18 and 8014-O are two conditions of the same aluminum grade, 8014: H18 (strain hardened, full hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 8014-H18 is the stronger of the two: yield strength 152 MPa (22 ksi) against 40 MPa (5.8 ksi) for 8014-O, about 3.8 times as much; tensile strength follows at 168 MPa (24.4 ksi) vs 95 MPa (13.8 ksi). In exchange, 8014-O is the more ductile: elongation 25% versus 3% for 8014-H18, and 8014-H18 is harder (50 HB vs 23 HB). 8014-O runs hotter in service (180°C vs 120°C continuous). On the shop floor, 8014-H18 machines more easily (fair vs poor).

8014-H18Choose it when strength drives the design, or when the part is machined in volume.

8014-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

8014-H18 vs 8014-O: properties

8014-H188014-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

168 MPa24.4 ksi
95 MPa13.8 ksi

Yield Strength (0.2% offset)

152 MPa22 ksi
40 MPa5.8 ksi

Elongation at Break

3%
25%

Shear Strength

100 MPa14.5 ksi
62 MPa9 ksi

Fatigue Strength (Endurance Limit)

62 MPa9 ksi
40 MPa5.8 ksi

Hardness, Brinell

50 HB
23 HB

Hardness, Vickers

55 HV
25 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

196 W/m·K113 BTU/hr·ft·°F
212 W/m·K122 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
180°C356 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.5 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

51.5 % IACS
55 % IACS

Electrical Resistivity

3.35×10⁻⁸ Ω·m1.32 µΩ·in
3.3×10⁻⁸ Ω·m1.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.76 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

38%
30%

Weldability

65 / 100
70 / 100

Formability (cold)

35 / 100
95 / 100

Same in both: Brazeability / Solderability 75 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale8014

8014-H18 vs 8014-O — frequently asked

Is 8014-H18 stronger than 8014-O?

Yes. 8014-H18 has a typical yield strength of 152 MPa (22 ksi) against 40 MPa (5.8 ksi) for 8014-O — about 3.8 times as much. Tensile strength is 168 MPa (24.4 ksi) vs 95 MPa (13.8 ksi).

Which condition does FabDigit quote by default, H18 or O?

H24 is the default 8014 condition in the FabDigit quote flow (neither H18 nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 8014-H18 or 8014-O?

8014-H18. Its machinability rates fair (40/100) against poor (25/100) for 8014-O; for welding the order is 8014-O first (very good, 70/100) then 8014-H18 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8014-H18 and 8014-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.