FabDigitFabDigit

Aluminum 7N01-O vs 7N01-T4

Aluminum · 7N01 temper comparison

7N01-O and 7N01-T4 are two conditions of the same aluminum grade, 7N01: O (annealed) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. 7N01-T4 is the stronger of the two: yield strength 210 MPa (30.5 ksi) against 120 MPa (17.4 ksi) for 7N01-O, about 75% more; tensile strength follows at 330 MPa (47.9 ksi) vs 225 MPa (32.6 ksi). In exchange, 7N01-O is the more ductile: elongation 20% versus 17% for 7N01-T4, and 7N01-T4 is harder (90 HB vs 65 HB). 7N01-O runs hotter in service (150°C vs 120°C continuous) and 7N01-O conducts heat better (160 W/m·K vs 130 W/m·K). On the shop floor, 7N01-T4 machines more easily (good vs fair) and 7N01-O welds better (excellent vs very good).

7N01-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

7N01-T4Choose it when strength drives the design, or when the part is machined in volume.

7N01-O vs 7N01-T4: properties

7N01-O7N01-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

225 MPa32.6 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

120 MPa17.4 ksi
210 MPa30.5 ksi

Elongation at Break

20%
17%

Compressive Strength

125 MPa18.1 ksi
290 MPa42.1 ksi

Shear Strength

150 MPa21.8 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
115 MPa16.7 ksi

Fracture Toughness (K_IC)

48 MPa·√m43.7 ksi·√in
33 MPa·√m30 ksi·√in

Hardness, Brinell

65 HB
90 HB

Hardness, Vickers

70 HV
112 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 600°C1,112 °F · Liquidus Temperature 645°C1,193 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

160 W/m·K92.4 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
32 % IACS

Electrical Resistivity

4.31×10⁻⁸ Ω·m1.7 µΩ·in
4.9×10⁻⁸ Ω·m1.93 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
38 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
60%

Weldability

90 / 100
80 / 100

Formability (cold)

80 / 100
62 / 100

Same in both: Castability 20 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7N01

7N01-O vs 7N01-T4 — frequently asked

Is 7N01-T4 stronger than 7N01-O?

Yes. 7N01-T4 has a typical yield strength of 210 MPa (30.5 ksi) against 120 MPa (17.4 ksi) for 7N01-O — about 75% more. Tensile strength is 330 MPa (47.9 ksi) vs 225 MPa (32.6 ksi).

Which condition does FabDigit quote by default, O or T4?

T5 is the default 7N01 condition in the FabDigit quote flow (neither O nor T4). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 7N01-O or 7N01-T4?

7N01-T4. Its machinability rates good (55/100) against fair (45/100) for 7N01-O; for welding the order is 7N01-O first (excellent, 90/100) then 7N01-T4 (very good, 80/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7N01-O and 7N01-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.