FabDigitFabDigit

Aluminum 7A52-T4 vs 7A52-T6

Aluminum · 7A52 temper comparison

7A52-T4 and 7A52-T6 are two conditions of the same aluminum grade, 7A52: T4 (solution heat treated and naturally aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 7A52-T6 is the stronger of the two: yield strength 390 MPa (56.6 ksi) against 240 MPa (34.8 ksi) for 7A52-T4, about 63% more; tensile strength follows at 460 MPa (66.7 ksi) vs 380 MPa (55.1 ksi). In exchange, 7A52-T4 is the more ductile: elongation 17% versus 12% for 7A52-T6, and 7A52-T6 is harder (135 HB vs 105 HB). 7A52-T6 conducts heat better (150 W/m·K vs 128 W/m·K).

7A52-T4Choose it when the part is bent, formed or impact-loaded.

7A52-T6Choose it when strength drives the design.

7A52-T4 vs 7A52-T6: properties

7A52-T47A52-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

380 MPa55.1 ksi
460 MPa66.7 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
390 MPa56.6 ksi

Elongation at Break

17%
12%

Shear Strength

235 MPa34.1 ksi
280 MPa40.6 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
150 MPa21.8 ksi

Hardness, Brinell

105 HB
135 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33 · Compressive Strength 400 MPa58 ksi · Fracture Toughness (K_IC) 32 MPa·√m29.1 ksi·√in · Hardness, Vickers 145 HV

Physical

Density and transition temperatures.

Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 640°C1,184 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

128 W/m·K74 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 960 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.5 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 120°C248 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

33 % IACS
40 % IACS

Same in both: Electrical Resistivity 4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
62 / 100

Formability (cold)

60 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 75 / 100 · Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7A52

7A52-T4 vs 7A52-T6 — frequently asked

Is 7A52-T6 stronger than 7A52-T4?

Yes. 7A52-T6 has a typical yield strength of 390 MPa (56.6 ksi) against 240 MPa (34.8 ksi) for 7A52-T4 — about 63% more. Tensile strength is 460 MPa (66.7 ksi) vs 380 MPa (55.1 ksi).

Which condition does FabDigit quote by default, T4 or T6?

T6 is the default 7A52 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 7A52-T4 or 7A52-T6?

7A52-T6, by a small margin. Both rate good for machinability — 62/100 against 55/100 for 7A52-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7A52-T4 and 7A52-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.