FabDigitFabDigit

Aluminum 7449-T6 vs 7449-T7651

Aluminum · 7449 temper comparison

7449-T6 and 7449-T7651 are two conditions of the same aluminum grade, 7449: T6 (solution heat treated and artificially aged) versus T7651 (T76, stress relieved by stretching). The chemistry is identical, so every difference below comes from the condition. Both yield at about 620 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (solution heat treated and artificially aged versus T76, stress relieved by stretching). 7449-T7651 is the more ductile: elongation 9% versus 8% for 7449-T6, and 7449-T6 is harder (205 HV vs 190 HV). 7449-T7651 conducts heat better (145 W/m·K vs 130 W/m·K).

7449-T7651Choose it when the part is bent, formed or impact-loaded.

7449-T6 vs 7449-T7651: properties

7449-T67449-T7651

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

660 MPa95.7 ksi
640 MPa92.8 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
605 MPa87.7 ksi

Elongation at Break

8%
9%

Shear Strength

375 MPa54.4 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

175 MPa25.4 ksi
172 MPa24.9 ksi

Fracture Toughness (K_IC)

25 MPa·√m22.8 ksi·√in
28 MPa·√m25.5 ksi·√in

Hardness, Brinell

195 HB
188 HB

Hardness, Vickers

205 HV
190 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 595 MPa86.3 ksi

Physical

Density and transition temperatures.

Same in both: Density 2.82 g/cm³0.1 lb/in³ · Melting Point (Solidus) 475°C887 °F · Liquidus Temperature 635°C1,175 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

130 W/m·K75.1 BTU/hr·ft·°F
145 W/m·K83.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 860 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 120°C248 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

31 % IACS
35 % IACS

Same in both: Electrical Resistivity 4.5×10⁻⁸ Ω·m1.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

32 / 100
42 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

78 / 100
79 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 80% · Weldability 18 / 100 · Formability (cold) 22 / 100 · Brazeability / Solderability 10 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 12%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7449

7449-T6 vs 7449-T7651 — frequently asked

What is the difference between 7449-T6 and 7449-T7651?

7449-T6 and 7449-T7651 are two conditions of the same aluminum grade, 7449: T6 (solution heat treated and artificially aged) versus T7651 (T76, stress relieved by stretching). The chemistry is identical, so every difference below comes from the condition. Both yield at about 620 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (solution heat treated and artificially aged versus T76, stress relieved by stretching).

Which condition does FabDigit quote by default, T6 or T7651?

T7951 is the default 7449 condition in the FabDigit quote flow (neither T6 nor T7651). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 7449-T6 over 7449-T7651?

Pick 7449-T7651 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7449-T6 and 7449-T7651 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.