FabDigitFabDigit

Aluminum 7079-O vs 7079-T6511

Aluminum · 7079 temper comparison

7079-O and 7079-T6511 are two conditions of the same aluminum grade, 7079: O (annealed) versus T6511 (T6, stress relieved by stretching, minor straightening). The chemistry is identical, so every difference below comes from the condition. 7079-T6511 is the stronger of the two: yield strength 460 MPa (66.7 ksi) against 110 MPa (16 ksi) for 7079-O, about 4.2 times as much; tensile strength follows at 530 MPa (76.9 ksi) vs 235 MPa (34.1 ksi). In exchange, 7079-O is the more ductile: elongation 16% versus 10% for 7079-T6511, and 7079-T6511 is harder (143 HB vs 62 HB). 7079-O conducts heat better (175 W/m·K vs 121 W/m·K). On the shop floor, 7079-T6511 machines more easily (very good vs fair).

7079-OChoose it when the part is bent, formed or impact-loaded.

7079-T6511Choose it when strength drives the design, or when the part is machined in volume.

7079-O vs 7079-T6511: properties

7079-O7079-T6511

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

235 MPa34.1 ksi
530 MPa76.9 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
460 MPa66.7 ksi

Elongation at Break

16%
10%

Compressive Strength

480 MPa69.6 ksi
470 MPa68.2 ksi

Shear Strength

150 MPa21.8 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

215 MPa31.2 ksi
210 MPa30.5 ksi

Fracture Toughness (K_IC)

30 MPa·√m27.3 ksi·√in
28 MPa·√m25.5 ksi·√in

Hardness, Brinell

62 HB
143 HB

Same in both: Elastic (Young's) Modulus 71.7 GPa10.4 Msi · Shear Modulus 26.9 GPa3.9 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33 · Reduction in Area 22%

Physical

Density and transition temperatures.

Same in both: Density 2.74 g/cm³0.1 lb/in³ · Melting Point (Solidus) 477°C891 °F · Liquidus Temperature 635°C1,175 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

175 W/m·K101 BTU/hr·ft·°F
121 W/m·K69.9 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 960 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24.3 µm/m·K13.5 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 120°C248 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

45 % IACS
33.5 % IACS

Same in both: Electrical Resistivity 5.15×10⁻⁸ Ω·m2.03 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

40 / 100
30 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
74 / 100

Formability (cold)

62 / 100
22 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 80% · Weldability 15 / 100 · Castability 25 / 100 · Brazeability / Solderability 10 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 8%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7079

7079-O vs 7079-T6511 — frequently asked

Is 7079-T6511 stronger than 7079-O?

Yes. 7079-T6511 has a typical yield strength of 460 MPa (66.7 ksi) against 110 MPa (16 ksi) for 7079-O — about 4.2 times as much. Tensile strength is 530 MPa (76.9 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, O or T6511?

T6 is the default 7079 condition in the FabDigit quote flow (neither O nor T6511). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 7079-O or 7079-T6511?

7079-T6511. Its machinability rates very good (74/100) against fair (45/100) for 7079-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7079-O and 7079-T6511 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.