FabDigitFabDigit

Aluminum 7076-F vs 7076-T61

Aluminum · 7076 temper comparison

7076-F and 7076-T61 are two conditions of the same aluminum grade, 7076: F (as fabricated) versus T61 (T6 variant, underaged). The chemistry is identical, so every difference below comes from the condition. 7076-T61 is the stronger of the two: yield strength 448 MPa (65 ksi) against 180 MPa (26.1 ksi) for 7076-F, about 149% more; tensile strength follows at 510 MPa (74 ksi) vs 300 MPa (43.5 ksi). 7076-T61 is harder — 142 HB against 85 HB for 7076-F — which matters for wear surfaces and threads. 7076-F runs hotter in service (150°C vs 120°C continuous) and 7076-F conducts heat better (168 W/m·K vs 150 W/m·K). On the shop floor, 7076-T61 machines more easily (very good vs good) and 7076-F forms better (fair vs poor).

7076-FChoose it when the part sees heat.

7076-T61Choose it when strength drives the design, or when surface hardness matters.

7076-F vs 7076-T61: properties

7076-F7076-T61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

300 MPa43.5 ksi
510 MPa74 ksi

Yield Strength (0.2% offset)

180 MPa26.1 ksi
448 MPa65 ksi

Compressive Strength

185 MPa26.8 ksi
455 MPa66 ksi

Shear Strength

190 MPa27.6 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
160 MPa23.2 ksi

Fracture Toughness (K_IC)

32 MPa·√m29.1 ksi·√in
26 MPa·√m23.7 ksi·√in

Hardness, Brinell

85 HB
142 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Elongation at Break 12%

Physical

Density and transition temperatures.

Same in both: Density 2.8 g/cm³0.1 lb/in³ · Melting Point (Solidus) 475°C887 °F · Liquidus Temperature 635°C1,175 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

168 W/m·K97.1 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 960 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
33 % IACS

Electrical Resistivity

4.3×10⁻⁸ Ω·m1.69 µΩ·in
5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

40 / 100
35 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.82 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
90%

Weldability

25 / 100
20 / 100

Formability (cold)

40 / 100
25 / 100

Same in both: Brazeability / Solderability 10 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7076

7076-F vs 7076-T61 — frequently asked

Is 7076-T61 stronger than 7076-F?

Yes. 7076-T61 has a typical yield strength of 448 MPa (65 ksi) against 180 MPa (26.1 ksi) for 7076-F — about 149% more. Tensile strength is 510 MPa (74 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, F or T61?

T61 is the default 7076 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 7076-F or 7076-T61?

7076-T61. Its machinability rates very good (70/100) against good (55/100) for 7076-F; for welding the order is 7076-F first (poor, 25/100) then 7076-T61 (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7076-F and 7076-T61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.