FabDigitFabDigit

Aluminum 707.0-F vs 707.0-T5

Aluminum · 707.0 temper comparison

707.0-F and 707.0-T5 are two conditions of the same aluminum grade, 707.0: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. 707.0-T5 is the stronger of the two: yield strength 193 MPa (28 ksi) against 140 MPa (20.3 ksi) for 707.0-F, about 38% more; tensile strength follows at 240 MPa (34.8 ksi) vs 205 MPa (29.7 ksi). In exchange, 707.0-F is the more ductile: elongation 3% versus 2% for 707.0-T5, and 707.0-T5 is harder (75 HB vs 60 HB). 707.0-T5 runs hotter in service (150°C vs 120°C continuous).

707.0-FChoose it when the part is bent, formed or impact-loaded.

707.0-T5Choose it when strength drives the design, or when the part sees heat.

707.0-F vs 707.0-T5: properties

707.0-F707.0-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

205 MPa29.7 ksi
240 MPa34.8 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
193 MPa28 ksi

Elongation at Break

3%
2%

Shear Strength

150 MPa21.8 ksi
175 MPa25.4 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
83 MPa12 ksi

Hardness, Brinell

60 HB
75 HB

Same in both: Elastic (Young's) Modulus 70.5 GPa10.2 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 200 MPa29 ksi · Fracture Toughness (K_IC) 20 MPa·√m18.2 ksi·√in · Charpy V-Notch Impact (RT) 5 J3.7 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.9 g/cm³0.1 lb/in³ · Melting Point (Solidus) 599°C1,110 °F · Liquidus Temperature 643°C1,189 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

125 W/m·K72.2 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

32 % IACS
35 % IACS

Same in both: Electrical Resistivity 4.9×10⁻⁸ Ω·m1.93 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
78 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 40 / 100 · Formability (cold) 10 / 100 · Castability 35 / 100 · Brazeability / Solderability 20 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale707.0

707.0-F vs 707.0-T5 — frequently asked

Is 707.0-T5 stronger than 707.0-F?

Yes. 707.0-T5 has a typical yield strength of 193 MPa (28 ksi) against 140 MPa (20.3 ksi) for 707.0-F — about 38% more. Tensile strength is 240 MPa (34.8 ksi) vs 205 MPa (29.7 ksi).

Which condition does FabDigit quote by default, F or T5?

T5 is the default 707.0 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 707.0-F or 707.0-T5?

707.0-T5, by a small margin. Both rate very good for machinability — 78/100 against 72/100 for 707.0-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 707.0-F and 707.0-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.