FabDigitFabDigit

Aluminum 7021-O vs 7021-T6

Aluminum · 7021 temper comparison

7021-O and 7021-T6 are two conditions of the same aluminum grade, 7021: O (annealed) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 7021-T6 is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 115 MPa (16.7 ksi) for 7021-O, about 3.2 times as much; tensile strength follows at 415 MPa (60.2 ksi) vs 230 MPa (33.4 ksi). In exchange, 7021-O is the more ductile: elongation 20% versus 12% for 7021-T6, and 7021-T6 is harder (125 HB vs 60 HB). 7021-O conducts heat better (170 W/m·K vs 140 W/m·K). On the shop floor, 7021-T6 machines more easily (good vs fair).

7021-OChoose it when the part is bent, formed or impact-loaded.

7021-T6Choose it when strength drives the design, or when the part is machined in volume.

7021-O vs 7021-T6: properties

7021-O7021-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

230 MPa33.4 ksi
415 MPa60.2 ksi

Yield Strength (0.2% offset)

115 MPa16.7 ksi
370 MPa53.7 ksi

Elongation at Break

20%
12%

Shear Strength

150 MPa21.8 ksi
250 MPa36.3 ksi

Hardness, Brinell

60 HB
125 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33 · Compressive Strength 375 MPa54.4 ksi · Fatigue Strength (Endurance Limit) 130 MPa18.9 ksi · Fracture Toughness (K_IC) 30 MPa·√m27.3 ksi·√in · Hardness, Vickers 135 HV

Physical

Density and transition temperatures.

Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 600°C1,112 °F · Liquidus Temperature 645°C1,193 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

170 W/m·K98.2 BTU/hr·ft·°F
140 W/m·K80.9 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 120°C248 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
33 % IACS

Same in both: Electrical Resistivity 5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

50 / 100
45 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
62 / 100

Formability (cold)

70 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 70 / 100 · Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7021

7021-O vs 7021-T6 — frequently asked

Is 7021-T6 stronger than 7021-O?

Yes. 7021-T6 has a typical yield strength of 370 MPa (53.7 ksi) against 115 MPa (16.7 ksi) for 7021-O — about 3.2 times as much. Tensile strength is 415 MPa (60.2 ksi) vs 230 MPa (33.4 ksi).

Which condition does FabDigit quote by default, O or T6?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 7021-O or 7021-T6?

7021-T6. Its machinability rates good (62/100) against fair (40/100) for 7021-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7021-O and 7021-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.