Aluminum · 7017 temper comparison

7017-T6 and 7017-T7351 are two conditions of the same aluminum grade, 7017: T6 (solution heat treated and artificially aged) versus T7351 (T73, stress relieved by stretching). The chemistry is identical, so every difference below comes from the condition. 7017-T6 is the stronger of the two: yield strength 400 MPa (58 ksi) against 340 MPa (49.3 ksi) for 7017-T7351, about 18% more; tensile strength follows at 460 MPa (66.7 ksi) vs 412 MPa (59.8 ksi). 7017-T6 is harder — 140 HB against 126 HB for 7017-T7351 — which matters for wear surfaces and threads. 7017-T7351 runs hotter in service (150°C vs 120°C continuous) and 7017-T7351 conducts heat better (155 W/m·K vs 138 W/m·K).

7017-T6Choose it when strength drives the design, or when surface hardness matters.

7017-T7351Choose it when the part sees heat.

7017-T6 vs 7017-T7351: properties

7017-T67017-T7351

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

460 MPa66.7 ksi
412 MPa59.8 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
340 MPa49.3 ksi

Elongation at Break

11%
12%

Shear Strength

280 MPa40.6 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

145 MPa21 ksi
128 MPa18.6 ksi

Fracture Toughness (K_IC)

31 MPa·√m28.2 ksi·√in
39 MPa·√m35.5 ksi·√in

Hardness, Brinell

140 HB
126 HB

Hardness, Vickers

152 HV
150 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 590°C1,094 °F · Liquidus Temperature 640°C1,184 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

138 W/m·K79.7 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

32 % IACS
38 % IACS

Same in both: Electrical Resistivity 5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

42 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
68 / 100

Formability (cold)

30 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 72 / 100 · Castability 30 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7017

7017-T6 vs 7017-T7351 — frequently asked

Is 7017-T6 stronger than 7017-T7351?

Yes. 7017-T6 has a typical yield strength of 400 MPa (58 ksi) against 340 MPa (49.3 ksi) for 7017-T7351 — about 18% more. Tensile strength is 460 MPa (66.7 ksi) vs 412 MPa (59.8 ksi).

Which condition does FabDigit quote by default, T6 or T7351?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose 7017-T6 over 7017-T7351?

Pick 7017-T6 when strength drives the design, or when surface hardness matters. Pick 7017-T7351 when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7017-T6 and 7017-T7351 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.