FabDigitFabDigit

Aluminum 7005-O vs 7005-T6

Aluminum · 7005 temper comparison

7005-O and 7005-T6 are two conditions of the same aluminum grade, 7005: O (annealed) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 7005-T6 is the stronger of the two: yield strength 295 MPa (42.8 ksi) against 85 MPa (12.3 ksi) for 7005-O, about 3.5 times as much; tensile strength follows at 350 MPa (50.8 ksi) vs 195 MPa (28.3 ksi). In exchange, 7005-O is the more ductile: elongation 20% versus 12% for 7005-T6, and 7005-T6 is harder (94 HB vs 45 HB). 7005-O conducts electricity better (45 % IACS vs 40 % IACS). On the shop floor, 7005-T6 machines more easily (good vs fair).

7005-OChoose it when the part is bent, formed or impact-loaded.

7005-T6Choose it when strength drives the design, or when the part is machined in volume.

7005-O vs 7005-T6: properties

7005-O7005-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

195 MPa28.3 ksi
350 MPa50.8 ksi

Yield Strength (0.2% offset)

85 MPa12.3 ksi
295 MPa42.8 ksi

Elongation at Break

20%
12%

Shear Strength

125 MPa18.1 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

80 MPa11.6 ksi
150 MPa21.8 ksi

Hardness, Brinell

45 HB
94 HB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 300 MPa43.5 ksi · Fracture Toughness (K_IC) 30 MPa·√m27.3 ksi·√in · Hardness, Vickers 105 HV

Physical

Density and transition temperatures.

Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 645°C1,193 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

165 W/m·K95.3 BTU/hr·ft·°F
149 W/m·K86.1 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 120°C248 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

45 % IACS
40 % IACS

Same in both: Electrical Resistivity 4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

50 / 100
45 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
60 / 100

Formability (cold)

80 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 80 / 100 · Castability 25 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7005

7005-O vs 7005-T6 — frequently asked

Is 7005-T6 stronger than 7005-O?

Yes. 7005-T6 has a typical yield strength of 295 MPa (42.8 ksi) against 85 MPa (12.3 ksi) for 7005-O — about 3.5 times as much. Tensile strength is 350 MPa (50.8 ksi) vs 195 MPa (28.3 ksi).

Which condition does FabDigit quote by default, O or T6?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 7005-O or 7005-T6?

7005-T6. Its machinability rates good (60/100) against fair (35/100) for 7005-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7005-O and 7005-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.