FabDigitFabDigit

Aluminum 6B02-H112 vs 6B02-T651

Aluminum · 6B02 temper comparison

6B02-H112 and 6B02-T651 are two conditions of the same aluminum grade, 6B02: H112 (strain hardened from hot working only) versus T651 (T6, stress relieved by stretching). The chemistry is identical, so every difference below comes from the condition. 6B02-T651 is the stronger of the two: yield strength 240 MPa (34.8 ksi) against 95 MPa (13.8 ksi) for 6B02-H112, about 153% more; tensile strength follows at 270 MPa (39.2 ksi) vs 165 MPa (23.9 ksi). In exchange, 6B02-H112 is the more ductile: elongation 16% versus 11% for 6B02-T651, and 6B02-T651 is harder (95 HB vs 52 HB). 6B02-H112 runs hotter in service (200°C vs 150°C continuous) and 6B02-H112 conducts heat better (190 W/m·K vs 170 W/m·K). On the shop floor, 6B02-T651 machines more easily (good vs fair).

6B02-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

6B02-T651Choose it when strength drives the design, or when the part is machined in volume.

6B02-H112 vs 6B02-T651: properties

6B02-H1126B02-T651

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

165 MPa23.9 ksi
270 MPa39.2 ksi

Yield Strength (0.2% offset)

95 MPa13.8 ksi
240 MPa34.8 ksi

Elongation at Break

16%
11%

Compressive Strength

95 MPa13.8 ksi
240 MPa34.8 ksi

Shear Strength

110 MPa16 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

62 MPa9 ksi
92 MPa13.3 ksi

Fracture Toughness (K_IC)

35 MPa·√m31.9 ksi·√in
29 MPa·√m26.4 ksi·√in

Charpy V-Notch Impact (RT)

28 J20.7 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

52 HB
95 HB

Hardness, Rockwell B

24 HRB
58 HRB

Hardness, Vickers

55 HV
100 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

190 W/m·K110 BTU/hr·ft·°F
170 W/m·K98.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 896 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

49 % IACS
43 % IACS

Electrical Resistivity

3.52×10⁻⁸ Ω·m1.39 µΩ·in
4×10⁻⁸ Ω·m1.57 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

70 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.75 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
52%

Weldability

80 / 100
75 / 100

Formability (cold)

65 / 100
38 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 55 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6B02

6B02-H112 vs 6B02-T651 — frequently asked

Is 6B02-T651 stronger than 6B02-H112?

Yes. 6B02-T651 has a typical yield strength of 240 MPa (34.8 ksi) against 95 MPa (13.8 ksi) for 6B02-H112 — about 153% more. Tensile strength is 270 MPa (39.2 ksi) vs 165 MPa (23.9 ksi).

Which condition does FabDigit quote by default, H112 or T651?

T6 is the default 6B02 condition in the FabDigit quote flow (neither H112 nor T651). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6B02-H112 or 6B02-T651?

6B02-T651. Its machinability rates good (60/100) against fair (42/100) for 6B02-H112; for welding the order is 6B02-H112 first (very good, 80/100) then 6B02-T651 (very good, 75/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6B02-H112 and 6B02-T651 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.