6A02-T4 and 6A02-T62 are two conditions of the same aluminum grade, 6A02: T4 (solution heat treated and naturally aged) versus T62 (T6, heat treated by the user). The chemistry is identical, so every difference below comes from the condition. 6A02-T62 is the stronger of the two: yield strength 245 MPa (35.5 ksi) against 120 MPa (17.4 ksi) for 6A02-T4, about 104% more; tensile strength follows at 315 MPa (45.7 ksi) vs 215 MPa (31.2 ksi). In exchange, 6A02-T4 is the more ductile: elongation 20% versus 12% for 6A02-T62, and 6A02-T62 is harder (93 HB vs 65 HB). 6A02-T62 runs hotter in service (150°C vs 100°C continuous). On the shop floor, 6A02-T62 machines more easily (good vs fair).

6A02-T4Choose it when the part is bent, formed or impact-loaded.

6A02-T62Choose it when strength drives the design, or when the part sees heat.

6A02-T4 vs 6A02-T62: properties

6A02-T46A02-T62

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

215 MPa31.2 ksi
315 MPa45.7 ksi

Yield Strength (0.2% offset)

120 MPa17.4 ksi
245 MPa35.5 ksi

Elongation at Break

20%
12%

Reduction in Area

35%
34%

Compressive Strength

255 MPa37 ksi
250 MPa36.3 ksi

Shear Strength

145 MPa21 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
90 MPa13.1 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
19 J14 ft·lbf

Hardness, Brinell

65 HB
93 HB

Hardness, Rockwell B

60 HRB
59 HRB

Hardness, Vickers

100 HV
98 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 29 MPa·√m26.4 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

155 W/m·K89.6 BTU/hr·ft·°F
165 W/m·K95.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 896 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
43 % IACS

Same in both: Electrical Resistivity 4×10⁻⁸ Ω·m1.57 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
62 / 100

Weldability

75 / 100
72 / 100

Formability (cold)

70 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 190% · Castability 35 / 100 · Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6A02

6A02-T4 vs 6A02-T62 — frequently asked

Is 6A02-T62 stronger than 6A02-T4?

Yes. 6A02-T62 has a typical yield strength of 245 MPa (35.5 ksi) against 120 MPa (17.4 ksi) for 6A02-T4 — about 104% more. Tensile strength is 315 MPa (45.7 ksi) vs 215 MPa (31.2 ksi).

Which condition does FabDigit quote by default, T4 or T62?

T6 is the default 6A02 condition in the FabDigit quote flow (neither T4 nor T62). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6A02-T4 or 6A02-T62?

6A02-T62. Its machinability rates good (62/100) against fair (52/100) for 6A02-T4.