Aluminum 6360-T4 vs 6360-T6

Aluminum · 6360 temper comparison

6360-T4 and 6360-T6 are two conditions of the same aluminum grade, 6360: T4 (solution heat treated and naturally aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6360-T6 is the stronger of the two: yield strength 190 MPa (27.6 ksi) against 90 MPa (13.1 ksi) for 6360-T4, about 111% more; tensile strength follows at 230 MPa (33.4 ksi) vs 160 MPa (23.2 ksi). In exchange, 6360-T4 is the more ductile: elongation 20% versus 11% for 6360-T6, and 6360-T6 is harder (75 HB vs 52 HB). 6360-T6 runs hotter in service (150°C vs 100°C continuous) and 6360-T6 conducts heat better (200 W/m·K vs 175 W/m·K). On the shop floor, 6360-T6 machines more easily (good vs fair).

6360-T4Choose it when the part is bent, formed or impact-loaded.

6360-T6Choose it when strength drives the design, or when the part sees heat.

6360-T4 vs 6360-T6: properties

6360-T46360-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

160 MPa23.2 ksi
230 MPa33.4 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
190 MPa27.6 ksi

Elongation at Break

20%
11%

Shear Strength

105 MPa15.2 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
68 MPa9.9 ksi

Hardness, Brinell

52 HB
75 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Compressive Strength 190 MPa27.6 ksi · Fracture Toughness (K_IC) 30 MPa·√m27.3 ksi·√in · Hardness, Vickers 80 HV

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 600°C1,112 °F · Liquidus Temperature 653°C1,207 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

175 W/m·K101 BTU/hr·ft·°F
200 W/m·K116 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

46 % IACS
53 % IACS

Electrical Resistivity

3.75×10⁻⁸ Ω·m1.48 µΩ·in
3.25×10⁻⁸ Ω·m1.28 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

130%
190%

Formability (cold)

85 / 100
60 / 100

Same in both: Weldability 85 / 100 · Castability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6360

6360-T4 vs 6360-T6 — frequently asked

Is 6360-T6 stronger than 6360-T4?

Yes. 6360-T6 has a typical yield strength of 190 MPa (27.6 ksi) against 90 MPa (13.1 ksi) for 6360-T4 — about 111% more. Tensile strength is 230 MPa (33.4 ksi) vs 160 MPa (23.2 ksi).

Which condition does FabDigit quote by default, T4 or T6?

T6 is the default 6360 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6360-T4 or 6360-T6?

6360-T6. Its machinability rates good (55/100) against fair (40/100) for 6360-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6360-T4 and 6360-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.