6262-T6511 and 6262-T8 are two conditions of the same aluminum grade, 6262: T6511 (T6, stress relieved by stretching, minor straightening) versus T8 (solution heat treated, cold worked and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6262-T8 is the stronger of the two: yield strength 365 MPa (52.9 ksi) against 275 MPa (39.9 ksi) for 6262-T6511, about 33% more; tensile strength follows at 395 MPa (57.3 ksi) vs 310 MPa (45 ksi). 6262-T8 is harder — 118 HB against 95 HB for 6262-T6511 — which matters for wear surfaces and threads. On the shop floor, 6262-T6511 forms better (fair vs poor).

6262-T8Choose it when strength drives the design, or when surface hardness matters.

6262-T6511 vs 6262-T8: properties

6262-T65116262-T8

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
395 MPa57.3 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
365 MPa52.9 ksi

Shear Strength

205 MPa29.7 ksi
235 MPa34.1 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
95 MPa13.8 ksi

Hardness, Brinell

95 HB
118 HB

Hardness, Vickers

105 HV
128 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Elongation at Break 10%

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 582°C1,080 °F · Liquidus Temperature 652°C1,206 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 172 W/m·K99.4 BTU/hr·ft·°F · Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 44 % IACS · Electrical Resistivity 3.9×10⁻⁸ Ω·m1.54 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
63 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

88 / 100
92 / 100

Machinability Rating (AISI 1212 = 100 %)

180%
190%

Weldability

30 / 100
25 / 100

Formability (cold)

35 / 100
25 / 100

Same in both: Brazeability / Solderability 30 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6262

6262-T6511 vs 6262-T8 — frequently asked

Is 6262-T8 stronger than 6262-T6511?

Yes. 6262-T8 has a typical yield strength of 365 MPa (52.9 ksi) against 275 MPa (39.9 ksi) for 6262-T6511 — about 33% more. Tensile strength is 395 MPa (57.3 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, T6511 or T8?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which welds better, 6262-T6511 or 6262-T8?

6262-T6511. Its weldability rates poor (30/100) against poor (25/100) for 6262-T8.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6262-T6511 and 6262-T8 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.