FabDigitFabDigit

Aluminum 6253-O vs 6253-T4

Aluminum · 6253 temper comparison

6253-O and 6253-T4 are two conditions of the same aluminum grade, 6253: O (annealed) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. 6253-T4 is the stronger of the two: yield strength 110 MPa (16 ksi) against 55 MPa (7.98 ksi) for 6253-O, about 100% more; tensile strength follows at 200 MPa (29 ksi) vs 110 MPa (16 ksi). In exchange, 6253-O is the more ductile: elongation 25% versus 20% for 6253-T4, and 6253-T4 is harder (60 HB vs 28 HB). 6253-O runs hotter in service (200°C vs 120°C continuous) and 6253-O conducts heat better (185 W/m·K vs 155 W/m·K). On the shop floor, 6253-T4 machines more easily (50 vs 35 out of 100).

6253-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

6253-T4Choose it when strength drives the design, or when the part is machined in volume.

6253-O vs 6253-T4: properties

6253-O6253-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

110 MPa16 ksi
200 MPa29 ksi

Yield Strength (0.2% offset)

55 MPa8 ksi
110 MPa16 ksi

Elongation at Break

25%
20%

Shear Strength

75 MPa10.9 ksi
130 MPa18.9 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
80 MPa11.6 ksi

Hardness, Brinell

28 HB
60 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 590°C1,094 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

185 W/m·K107 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
120°C248 °F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

46 % IACS
37 % IACS

Electrical Resistivity

3.7×10⁻⁸ Ω·m1.46 µΩ·in
4.7×10⁻⁸ Ω·m1.85 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.9 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
50 / 100

Formability (cold)

90 / 100
70 / 100

Same in both: Weldability 65 / 100 · Brazeability / Solderability 50 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6253

6253-O vs 6253-T4 — frequently asked

Is 6253-T4 stronger than 6253-O?

Yes. 6253-T4 has a typical yield strength of 110 MPa (16 ksi) against 55 MPa (7.98 ksi) for 6253-O — about 100% more. Tensile strength is 200 MPa (29 ksi) vs 110 MPa (16 ksi).

Which condition does FabDigit quote by default, O or T4?

T6 is the default 6253 condition in the FabDigit quote flow (neither O nor T4). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6253-O or 6253-T4?

6253-T4, by a small margin. Both rate fair for machinability — 50/100 against 35/100 for 6253-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6253-O and 6253-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.