FabDigitFabDigit

Aluminum 6201-O vs 6201-T4

Aluminum · 6201 temper comparison

6201-O and 6201-T4 are two conditions of the same aluminum grade, 6201: O (annealed) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. 6201-T4 is the stronger of the two: yield strength 125 MPa (18.1 ksi) against 75 MPa (10.9 ksi) for 6201-O, about 67% more; tensile strength follows at 220 MPa (31.9 ksi) vs 145 MPa (21 ksi). In exchange, 6201-O is the more ductile: elongation 22% versus 18% for 6201-T4, and 6201-T4 is harder (62 HB vs 40 HB). 6201-O runs hotter in service (150°C vs 100°C continuous) and 6201-O conducts heat better (220 W/m·K vs 170 W/m·K). On the shop floor, 6201-T4 machines more easily (50 vs 40 out of 100).

6201-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

6201-T4Choose it when strength drives the design, or when the part is machined in volume.

6201-O vs 6201-T4: properties

6201-O6201-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

145 MPa21 ksi
220 MPa31.9 ksi

Yield Strength (0.2% offset)

75 MPa10.9 ksi
125 MPa18.1 ksi

Elongation at Break

22%
18%

Shear Strength

95 MPa13.8 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
90 MPa13.1 ksi

Fracture Toughness (K_IC)

29 MPa·√m26.4 ksi·√in
34 MPa·√m30.9 ksi·√in

Hardness, Brinell

40 HB
62 HB

Same in both: Elastic (Young's) Modulus 68.9 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.69 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

220 W/m·K127 BTU/hr·ft·°F
170 W/m·K98.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
100°C212 °F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23 µm/m·K12.8 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -80°C-112 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

57 % IACS
43 % IACS

Electrical Resistivity

3.02×10⁻⁸ Ω·m1.19 µΩ·in
4.01×10⁻⁸ Ω·m1.58 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
50 / 100

Weldability

62 / 100
68 / 100

Formability (cold)

85 / 100
65 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6201

6201-O vs 6201-T4 — frequently asked

Is 6201-T4 stronger than 6201-O?

Yes. 6201-T4 has a typical yield strength of 125 MPa (18.1 ksi) against 75 MPa (10.9 ksi) for 6201-O — about 67% more. Tensile strength is 220 MPa (31.9 ksi) vs 145 MPa (21 ksi).

Which condition does FabDigit quote by default, O or T4?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 6201-O or 6201-T4?

6201-T4, by a small margin. Both rate fair for machinability — 50/100 against 40/100 for 6201-O; for welding the order is 6201-T4 first (good, 68/100) then 6201-O (good, 62/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6201-O and 6201-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.