FabDigitFabDigit

Aluminum 6181-O vs 6181-T4

Aluminum · 6181 temper comparison

6181-O and 6181-T4 are two conditions of the same aluminum grade, 6181: O (annealed) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. 6181-T4 is the stronger of the two: yield strength 130 MPa (18.9 ksi) against 60 MPa (8.7 ksi) for 6181-O, about 117% more; tensile strength follows at 240 MPa (34.8 ksi) vs 125 MPa (18.1 ksi). In exchange, 6181-O is the more ductile: elongation 28% versus 25% for 6181-T4, and 6181-T4 is harder (70 HB vs 33 HB). 6181-O runs hotter in service (120°C vs 100°C continuous) and 6181-O conducts heat better (190 W/m·K vs 165 W/m·K). On the shop floor, 6181-T4 machines more easily (good vs fair).

6181-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

6181-T4Choose it when strength drives the design, or when the part is machined in volume.

6181-O vs 6181-T4: properties

6181-O6181-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

125 MPa18.1 ksi
240 MPa34.8 ksi

Yield Strength (0.2% offset)

60 MPa8.7 ksi
130 MPa18.9 ksi

Elongation at Break

28%
25%

Shear Strength

85 MPa12.3 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
90 MPa13.1 ksi

Hardness, Brinell

33 HB
70 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Hardness, Vickers 75 HV

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

190 W/m·K110 BTU/hr·ft·°F
165 W/m·K95.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
100°C212 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

50 % IACS
44 % IACS

Electrical Resistivity

3.45×10⁻⁸ Ω·m1.36 µΩ·in
3.9×10⁻⁸ Ω·m1.54 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.74 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
55 / 100

Weldability

78 / 100
75 / 100

Formability (cold)

92 / 100
80 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6181

6181-O vs 6181-T4 — frequently asked

Is 6181-T4 stronger than 6181-O?

Yes. 6181-T4 has a typical yield strength of 130 MPa (18.9 ksi) against 60 MPa (8.7 ksi) for 6181-O — about 117% more. Tensile strength is 240 MPa (34.8 ksi) vs 125 MPa (18.1 ksi).

Which condition does FabDigit quote by default, O or T4?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 6181-O or 6181-T4?

6181-T4. Its machinability rates good (55/100) against fair (40/100) for 6181-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6181-O and 6181-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.