FabDigitFabDigit

Aluminum 6070-T4 vs 6070-T6511

Aluminum · 6070 temper comparison

6070-T4 and 6070-T6511 are two conditions of the same aluminum grade, 6070: T4 (solution heat treated and naturally aged) versus T6511 (T6, stress relieved by stretching, minor straightening). The chemistry is identical, so every difference below comes from the condition. 6070-T6511 is the stronger of the two: yield strength 350 MPa (50.8 ksi) against 172 MPa (24.9 ksi) for 6070-T4, about 103% more; tensile strength follows at 380 MPa (55.1 ksi) vs 315 MPa (45.7 ksi). In exchange, 6070-T4 is the more ductile: elongation 20% versus 10% for 6070-T6511, and 6070-T6511 is harder (120 HB vs 90 HB). 6070-T6511 runs hotter in service (150°C vs 100°C continuous) and 6070-T6511 conducts heat better (172 W/m·K vs 154 W/m·K). On the shop floor, 6070-T6511 machines more easily (good vs fair).

6070-T4Choose it when the part is bent, formed or impact-loaded.

6070-T6511Choose it when strength drives the design, or when the part sees heat.

6070-T4 vs 6070-T6511: properties

6070-T46070-T6511

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

315 MPa45.7 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

172 MPa24.9 ksi
350 MPa50.8 ksi

Elongation at Break

20%
10%

Shear Strength

205 MPa29.7 ksi
235 MPa34.1 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
97 MPa14.1 ksi

Hardness, Brinell

90 HB
120 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 28 MPa·√m25.5 ksi·√in · Hardness, Vickers 128 HV

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 566°C1,051 °F · Liquidus Temperature 649°C1,200 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

154 W/m·K89 BTU/hr·ft·°F
172 W/m·K99.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.5 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

39 % IACS
44 % IACS

Electrical Resistivity

4.4×10⁻⁸ Ω·m1.73 µΩ·in
3.9×10⁻⁸ Ω·m1.54 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
65 / 100

Formability (cold)

60 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 200% · Weldability 70 / 100 · Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6070

6070-T4 vs 6070-T6511 — frequently asked

Is 6070-T6511 stronger than 6070-T4?

Yes. 6070-T6511 has a typical yield strength of 350 MPa (50.8 ksi) against 172 MPa (24.9 ksi) for 6070-T4 — about 103% more. Tensile strength is 380 MPa (55.1 ksi) vs 315 MPa (45.7 ksi).

Which condition does FabDigit quote by default, T4 or T6511?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 6070-T4 or 6070-T6511?

6070-T6511. Its machinability rates good (65/100) against fair (50/100) for 6070-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6070-T4 and 6070-T6511 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.