FabDigitFabDigit

Aluminum 6026-T4 vs 6026-T5

Aluminum · 6026 temper comparison

6026-T4 and 6026-T5 are two conditions of the same aluminum grade, 6026: T4 (solution heat treated and naturally aged) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6026-T5 is the stronger of the two: yield strength 255 MPa (37 ksi) against 150 MPa (21.8 ksi) for 6026-T4, about 70% more; tensile strength follows at 295 MPa (42.8 ksi) vs 255 MPa (37 ksi). In exchange, 6026-T4 is the more ductile: elongation 18% versus 11% for 6026-T5, and 6026-T5 is harder (88 HB vs 70 HB). 6026-T5 runs hotter in service (150°C vs 100°C continuous) and 6026-T5 conducts electricity better (44 % IACS vs 38 % IACS).

6026-T4Choose it when the part is bent, formed or impact-loaded.

6026-T5Choose it when strength drives the design, or when the part sees heat.

6026-T4 vs 6026-T5: properties

6026-T46026-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

255 MPa37 ksi
295 MPa42.8 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
255 MPa37 ksi

Elongation at Break

18%
11%

Shear Strength

165 MPa23.9 ksi
185 MPa26.8 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
95 MPa13.8 ksi

Hardness, Brinell

70 HB
88 HB

Same in both: Elastic (Young's) Modulus 69.5 GPa10.1 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 24 MPa·√m21.8 ksi·√in · Hardness, Vickers 118 HV

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

155 W/m·K89.6 BTU/hr·ft·°F
172 W/m·K99.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

38 % IACS
44 % IACS

Same in both: Electrical Resistivity 4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

82 / 100
88 / 100

Formability (cold)

50 / 100
22 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 95% · Weldability 20 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6026

6026-T4 vs 6026-T5 — frequently asked

Is 6026-T5 stronger than 6026-T4?

Yes. 6026-T5 has a typical yield strength of 255 MPa (37 ksi) against 150 MPa (21.8 ksi) for 6026-T4 — about 70% more. Tensile strength is 295 MPa (42.8 ksi) vs 255 MPa (37 ksi).

Which condition does FabDigit quote by default, T4 or T5?

T9 is the default 6026 condition in the FabDigit quote flow (neither T4 nor T5). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6026-T4 or 6026-T5?

6026-T5. Its machinability rates excellent (88/100) against very good (82/100) for 6026-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6026-T4 and 6026-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.