FabDigitFabDigit

Aluminum 6010-T4 vs 6010-T6

Aluminum · 6010 temper comparison

6010-T4 and 6010-T6 are two conditions of the same aluminum grade, 6010: T4 (solution heat treated and naturally aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6010-T6 is the stronger of the two: yield strength 310 MPa (45 ksi) against 170 MPa (24.7 ksi) for 6010-T4, about 82% more; tensile strength follows at 350 MPa (50.8 ksi) vs 290 MPa (42.1 ksi). In exchange, 6010-T4 is the more ductile: elongation 24% versus 12% for 6010-T6, and 6010-T6 is harder (105 HB vs 85 HB). 6010-T6 runs hotter in service (150°C vs 100°C continuous).

6010-T4Choose it when the part is bent, formed or impact-loaded.

6010-T6Choose it when strength drives the design, or when the part sees heat.

6010-T4 vs 6010-T6: properties

6010-T46010-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

290 MPa42.1 ksi
350 MPa50.8 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
310 MPa45 ksi

Elongation at Break

24%
12%

Shear Strength

195 MPa28.3 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
115 MPa16.7 ksi

Fracture Toughness (K_IC)

34 MPa·√m30.9 ksi·√in
29 MPa·√m26.4 ksi·√in

Hardness, Brinell

85 HB
105 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

180 W/m·K104 BTU/hr·ft·°F
190 W/m·K110 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

43 % IACS
45 % IACS

Same in both: Electrical Resistivity 4×10⁻⁸ Ω·m1.57 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.76 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
72 / 100

Weldability

60 / 100
55 / 100

Formability (cold)

80 / 100
45 / 100

Same in both: Brazeability / Solderability 35 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6010

6010-T4 vs 6010-T6 — frequently asked

Is 6010-T6 stronger than 6010-T4?

Yes. 6010-T6 has a typical yield strength of 310 MPa (45 ksi) against 170 MPa (24.7 ksi) for 6010-T4 — about 82% more. Tensile strength is 350 MPa (50.8 ksi) vs 290 MPa (42.1 ksi).

Which condition does FabDigit quote by default, T4 or T6?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 6010-T4 or 6010-T6?

6010-T6. Its machinability rates very good (72/100) against good (65/100) for 6010-T4; for welding the order is 6010-T4 first (good, 60/100) then 6010-T6 (good, 55/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6010-T4 and 6010-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.