FabDigitFabDigit

Aluminum 6010-O vs 6010-T4

Aluminum · 6010 temper comparison

6010-O and 6010-T4 are two conditions of the same aluminum grade, 6010: O (annealed) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. 6010-T4 is the stronger of the two: yield strength 170 MPa (24.7 ksi) against 70 MPa (10.2 ksi) for 6010-O, about 143% more; tensile strength follows at 290 MPa (42.1 ksi) vs 140 MPa (20.3 ksi). In exchange, 6010-O is the more ductile: elongation 28% versus 24% for 6010-T4, and 6010-T4 is harder (85 HB vs 40 HB). 6010-O runs hotter in service (120°C vs 100°C continuous) and 6010-O conducts heat better (200 W/m·K vs 180 W/m·K). On the shop floor, 6010-T4 machines more easily (good vs fair).

6010-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

6010-T4Choose it when strength drives the design, or when the part is machined in volume.

6010-O vs 6010-T4: properties

6010-O6010-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

140 MPa20.3 ksi
290 MPa42.1 ksi

Yield Strength (0.2% offset)

70 MPa10.2 ksi
170 MPa24.7 ksi

Elongation at Break

28%
24%

Shear Strength

95 MPa13.8 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
110 MPa16 ksi

Fracture Toughness (K_IC)

32 MPa·√m29.1 ksi·√in
34 MPa·√m30.9 ksi·√in

Hardness, Brinell

40 HB
85 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

200 W/m·K116 BTU/hr·ft·°F
180 W/m·K104 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
100°C212 °F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

48 % IACS
43 % IACS

Same in both: Electrical Resistivity 4×10⁻⁸ Ω·m1.57 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.76 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
65 / 100

Formability (cold)

92 / 100
80 / 100

Same in both: Weldability 60 / 100 · Brazeability / Solderability 35 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6010

6010-O vs 6010-T4 — frequently asked

Is 6010-T4 stronger than 6010-O?

Yes. 6010-T4 has a typical yield strength of 170 MPa (24.7 ksi) against 70 MPa (10.2 ksi) for 6010-O — about 143% more. Tensile strength is 290 MPa (42.1 ksi) vs 140 MPa (20.3 ksi).

Which condition does FabDigit quote by default, O or T4?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 6010-O or 6010-T4?

6010-T4. Its machinability rates good (65/100) against fair (45/100) for 6010-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6010-O and 6010-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.