FabDigitFabDigit

Aluminum 6008-T6 vs 6008-T61

Aluminum · 6008 temper comparison

6008-T6 and 6008-T61 are two conditions of the same aluminum grade, 6008: T6 (solution heat treated and artificially aged) versus T61 (T6 variant, underaged). The chemistry is identical, so every difference below comes from the condition. 6008-T6 is the stronger of the two: yield strength 235 MPa (34.1 ksi) against 190 MPa (27.6 ksi) for 6008-T61, about 24% more; tensile strength follows at 270 MPa (39.2 ksi) vs 245 MPa (35.5 ksi). In exchange, 6008-T61 is the more ductile: elongation 15% versus 12% for 6008-T6, and 6008-T6 is harder (90 HB vs 80 HB).

6008-T6Choose it when strength drives the design.

6008-T61Choose it when the part is bent, formed or impact-loaded.

6008-T6 vs 6008-T61: properties

6008-T66008-T61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

270 MPa39.2 ksi
245 MPa35.5 ksi

Yield Strength (0.2% offset)

235 MPa34.1 ksi
190 MPa27.6 ksi

Elongation at Break

12%
15%

Compressive Strength

235 MPa34.1 ksi
190 MPa27.6 ksi

Shear Strength

180 MPa26.1 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
80 MPa11.6 ksi

Fracture Toughness (K_IC)

29 MPa·√m26.4 ksi·√in
33 MPa·√m30 ksi·√in

Hardness, Brinell

90 HB
80 HB

Hardness, Vickers

95 HV
85 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

190 W/m·K110 BTU/hr·ft·°F
188 W/m·K109 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

50 % IACS
49 % IACS

Electrical Resistivity

3.45×10⁻⁸ Ω·m1.36 µΩ·in
3.52×10⁻⁸ Ω·m1.39 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
67 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.74 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

150%
135%

Formability (cold)

45 / 100
55 / 100

Same in both: Weldability 75 / 100 · Brazeability / Solderability 60 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 210 MJ/kg90,284 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6008

6008-T6 vs 6008-T61 — frequently asked

Is 6008-T6 stronger than 6008-T61?

Yes. 6008-T6 has a typical yield strength of 235 MPa (34.1 ksi) against 190 MPa (27.6 ksi) for 6008-T61 — about 24% more. Tensile strength is 270 MPa (39.2 ksi) vs 245 MPa (35.5 ksi).

Which condition does FabDigit quote by default, T6 or T61?

T6 is the default 6008 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6008-T6 or 6008-T61?

6008-T6, by a small margin. Both rate good for machinability — 60/100 against 55/100 for 6008-T61.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6008-T6 and 6008-T61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.