FabDigitFabDigit

Aluminum 5B05-AW vs 5B05-H14

Aluminum · 5B05 temper comparison

5B05-AW and 5B05-H14 are two conditions of the same aluminum grade, 5B05: AW (as-welded deposit) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5B05-H14 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 130 MPa (18.9 ksi) for 5B05-AW, about 92% more; tensile strength follows at 330 MPa (47.9 ksi) vs 275 MPa (39.9 ksi). In exchange, 5B05-AW is the more ductile: elongation 17% versus 8% for 5B05-H14, and 5B05-H14 is harder (88 HB vs 62 HB).

5B05-AWChoose it when the part is bent, formed or impact-loaded.

5B05-H14Choose it when strength drives the design.

5B05-AW vs 5B05-H14: properties

5B05-AW5B05-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

275 MPa39.9 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
250 MPa36.3 ksi

Elongation at Break

17%
8%

Shear Strength

160 MPa23.2 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
145 MPa21 ksi

Hardness, Brinell

62 HB
88 HB

Hardness, Vickers

66 HV
92 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.64 g/cm³0.1 lb/in³ · Melting Point (Solidus) 568°C1,054 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

65°C149 °F
70°C158 °F

Same in both: Thermal Conductivity 117 W/m·K67.6 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24.1 µm/m·K13.4 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

29 % IACS
28.5 % IACS

Electrical Resistivity

5.95×10⁻⁸ Ω·m2.34 µΩ·in
6.05×10⁻⁸ Ω·m2.38 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

70 / 100
66 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
33%

Weldability

88 / 100
82 / 100

Formability (cold)

70 / 100
40 / 100

Same in both: Brazeability / Solderability 15 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5B05

5B05-AW vs 5B05-H14 — frequently asked

Is 5B05-H14 stronger than 5B05-AW?

Yes. 5B05-H14 has a typical yield strength of 250 MPa (36.3 ksi) against 130 MPa (18.9 ksi) for 5B05-AW — about 92% more. Tensile strength is 330 MPa (47.9 ksi) vs 275 MPa (39.9 ksi).

Which condition does FabDigit quote by default, AW or H14?

O is the default 5B05 condition in the FabDigit quote flow (neither AW nor H14). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5B05-AW or 5B05-H14?

5B05-H14, by a small margin. Both rate fair for machinability — 50/100 against 42/100 for 5B05-AW; for welding the order is 5B05-AW first (excellent, 88/100) then 5B05-H14 (very good, 82/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5B05-AW and 5B05-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.