FabDigitFabDigit

Aluminum 5A03-H34 vs 5A03-O

Aluminum · 5A03 temper comparison

5A03-H34 and 5A03-O are two conditions of the same aluminum grade, 5A03: H34 (strain hardened and stabilized, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 5A03-H34 is the stronger of the two: yield strength 200 MPa (29 ksi) against 90 MPa (13.1 ksi) for 5A03-O, about 122% more; tensile strength follows at 255 MPa (37 ksi) vs 200 MPa (29 ksi). In exchange, 5A03-O is the more ductile: elongation 22% versus 9% for 5A03-H34, and 5A03-H34 is harder (73 HB vs 55 HB). 5A03-O runs hotter in service (120°C vs 65°C continuous). On the shop floor, 5A03-H34 machines more easily (52 vs 40 out of 100).

5A03-H34Choose it when strength drives the design, or when the part is machined in volume.

5A03-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5A03-H34 vs 5A03-O: properties

5A03-H345A03-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

255 MPa37 ksi
200 MPa29 ksi

Yield Strength (0.2% offset)

200 MPa29 ksi
90 MPa13.1 ksi

Elongation at Break

9%
22%

Shear Strength

150 MPa21.8 ksi
130 MPa18.9 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
115 MPa16.7 ksi

Hardness, Brinell

73 HB
55 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 575°C1,067 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

127 W/m·K73.4 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

65°C149 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.5 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

31 % IACS
32 % IACS

Electrical Resistivity

5.56×10⁻⁸ Ω·m2.19 µΩ·in
5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

70 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
40%

Weldability

88 / 100
90 / 100

Formability (cold)

55 / 100
90 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 25 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5A03

5A03-H34 vs 5A03-O — frequently asked

Is 5A03-H34 stronger than 5A03-O?

Yes. 5A03-H34 has a typical yield strength of 200 MPa (29 ksi) against 90 MPa (13.1 ksi) for 5A03-O — about 122% more. Tensile strength is 255 MPa (37 ksi) vs 200 MPa (29 ksi).

Which condition does FabDigit quote by default, H34 or O?

O is the default 5A03 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5A03-H34 or 5A03-O?

5A03-H34, by a small margin. Both rate fair for machinability — 52/100 against 40/100 for 5A03-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5A03-H34 and 5A03-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.