FabDigitFabDigit

Aluminum 5A03-H112 vs 5A03-H34

Aluminum · 5A03 temper comparison

5A03-H112 and 5A03-H34 are two conditions of the same aluminum grade, 5A03: H112 (strain hardened from hot working only) versus H34 (strain hardened and stabilized, half hard). The chemistry is identical, so every difference below comes from the condition. 5A03-H34 is the stronger of the two: yield strength 200 MPa (29 ksi) against 90 MPa (13.1 ksi) for 5A03-H112, about 122% more; tensile strength follows at 255 MPa (37 ksi) vs 195 MPa (28.3 ksi). In exchange, 5A03-H112 is the more ductile: elongation 18% versus 9% for 5A03-H34, and 5A03-H34 is harder (73 HB vs 55 HB). 5A03-H112 runs hotter in service (120°C vs 65°C continuous).

5A03-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5A03-H34Choose it when strength drives the design.

5A03-H112 vs 5A03-H34: properties

5A03-H1125A03-H34

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

195 MPa28.3 ksi
255 MPa37 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
200 MPa29 ksi

Elongation at Break

18%
9%

Shear Strength

128 MPa18.6 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
125 MPa18.1 ksi

Hardness, Brinell

55 HB
73 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 575°C1,067 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

130 W/m·K75.1 BTU/hr·ft·°F
127 W/m·K73.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
65°C149 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.5 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

32 % IACS
31 % IACS

Electrical Resistivity

5.4×10⁻⁸ Ω·m2.13 µΩ·in
5.56×10⁻⁸ Ω·m2.19 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
45%

Weldability

90 / 100
88 / 100

Formability (cold)

80 / 100
55 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 25 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5A03

5A03-H112 vs 5A03-H34 — frequently asked

Is 5A03-H34 stronger than 5A03-H112?

Yes. 5A03-H34 has a typical yield strength of 200 MPa (29 ksi) against 90 MPa (13.1 ksi) for 5A03-H112 — about 122% more. Tensile strength is 255 MPa (37 ksi) vs 195 MPa (28.3 ksi).

Which condition does FabDigit quote by default, H112 or H34?

O is the default 5A03 condition in the FabDigit quote flow (neither H112 nor H34). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5A03-H112 or 5A03-H34?

5A03-H34, by a small margin. Both rate fair for machinability — 52/100 against 45/100 for 5A03-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5A03-H112 and 5A03-H34 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.