FabDigitFabDigit

Aluminum 5A02-H112 vs 5A02-H34

Aluminum · 5A02 temper comparison

5A02-H112 and 5A02-H34 are two conditions of the same aluminum grade, 5A02: H112 (strain hardened from hot working only) versus H34 (strain hardened and stabilized, half hard). The chemistry is identical, so every difference below comes from the condition. 5A02-H34 is the stronger of the two: yield strength 185 MPa (26.8 ksi) against 90 MPa (13.1 ksi) for 5A02-H112, about 106% more; tensile strength follows at 240 MPa (34.8 ksi) vs 185 MPa (26.8 ksi). In exchange, 5A02-H112 is the more ductile: elongation 16% versus 10% for 5A02-H34, and 5A02-H34 is harder (65 HB vs 50 HB). 5A02-H112 runs hotter in service (120°C vs 110°C continuous). On the shop floor, 5A02-H34 machines more easily (fair vs poor).

5A02-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5A02-H34Choose it when strength drives the design, or when the part is machined in volume.

5A02-H112 vs 5A02-H34: properties

5A02-H1125A02-H34

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

185 MPa26.8 ksi
240 MPa34.8 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
185 MPa26.8 ksi

Elongation at Break

16%
10%

Shear Strength

128 MPa18.6 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
125 MPa18.1 ksi

Hardness, Brinell

50 HB
65 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

120°C248 °F
110°C230 °F

Same in both: Thermal Conductivity 138 W/m·K79.7 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 35 % IACS · Electrical Resistivity 4.9×10⁻⁸ Ω·m1.93 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
43 / 100

Machinability Rating (AISI 1212 = 100 %)

100%
120%

Formability (cold)

85 / 100
60 / 100

Same in both: Weldability 85 / 100 · Castability 25 / 100 · Brazeability / Solderability 25 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5A02

5A02-H112 vs 5A02-H34 — frequently asked

Is 5A02-H34 stronger than 5A02-H112?

Yes. 5A02-H34 has a typical yield strength of 185 MPa (26.8 ksi) against 90 MPa (13.1 ksi) for 5A02-H112 — about 106% more. Tensile strength is 240 MPa (34.8 ksi) vs 185 MPa (26.8 ksi).

Which condition does FabDigit quote by default, H112 or H34?

O is the default 5A02 condition in the FabDigit quote flow (neither H112 nor H34). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5A02-H112 or 5A02-H34?

5A02-H34. Its machinability rates fair (43/100) against poor (32/100) for 5A02-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5A02-H112 and 5A02-H34 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.