FabDigitFabDigit

Aluminum 5754-H32 vs 5754-O

Aluminum · 5754 temper comparison

5754-H32 and 5754-O are two conditions of the same aluminum grade, 5754: H32 (strain hardened and stabilized, quarter hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 5754-H32 is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 100 MPa (14.5 ksi) for 5754-O, about 50% more; tensile strength follows at 245 MPa (35.5 ksi) vs 210 MPa (30.5 ksi). In exchange, 5754-O is the more ductile: elongation 22% versus 13% for 5754-H32, and 5754-H32 is harder (66 HB vs 50 HB). 5754-O runs hotter in service (80°C vs 65°C continuous). On the shop floor, 5754-H32 machines more easily (fair vs poor).

5754-H32Choose it when strength drives the design, or when the part is machined in volume.

5754-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5754-H32 vs 5754-O: properties

5754-H325754-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

245 MPa35.5 ksi
210 MPa30.5 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
100 MPa14.5 ksi

Elongation at Break

13%
22%

Shear Strength

150 MPa21.8 ksi
135 MPa19.6 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
100 MPa14.5 ksi

Hardness, Brinell

66 HB
50 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 600°C1,112 °F · Liquidus Temperature 645°C1,193 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

147 W/m·K84.9 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

65°C149 °F
80°C176 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.7 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

35 % IACS
36 % IACS

Electrical Resistivity

4.93×10⁻⁸ Ω·m1.94 µΩ·in
4.79×10⁻⁸ Ω·m1.89 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

76 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
28%

Weldability

90 / 100
95 / 100

Formability (cold)

73 / 100
95 / 100

Same in both: Brazeability / Solderability 25 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5754

5754-H32 vs 5754-O — frequently asked

Is 5754-H32 stronger than 5754-O?

Yes. 5754-H32 has a typical yield strength of 150 MPa (21.8 ksi) against 100 MPa (14.5 ksi) for 5754-O — about 50% more. Tensile strength is 245 MPa (35.5 ksi) vs 210 MPa (30.5 ksi).

Which condition does FabDigit quote by default, H32 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5754-H32 or 5754-O?

5754-H32. Its machinability rates fair (45/100) against poor (32/100) for 5754-O; for welding the order is 5754-O first (excellent, 95/100) then 5754-H32 (excellent, 90/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5754-H32 and 5754-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.