FabDigitFabDigit

Aluminum 5754-H111 vs 5754-H14

Aluminum · 5754 temper comparison

5754-H111 and 5754-H14 are two conditions of the same aluminum grade, 5754: H111 (slightly strain hardened) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5754-H14 is the stronger of the two: yield strength 205 MPa (29.7 ksi) against 110 MPa (16 ksi) for 5754-H111, about 86% more; tensile strength follows at 260 MPa (37.7 ksi) vs 215 MPa (31.2 ksi). In exchange, 5754-H111 is the more ductile: elongation 20% versus 7% for 5754-H14, and 5754-H14 is harder (72 HB vs 55 HB). 5754-H111 runs hotter in service (80°C vs 65°C continuous). On the shop floor, 5754-H14 machines more easily (50 vs 40 out of 100).

5754-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5754-H14Choose it when strength drives the design, or when the part is machined in volume.

5754-H111 vs 5754-H14: properties

5754-H1115754-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

215 MPa31.2 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
205 MPa29.7 ksi

Elongation at Break

20%
7%

Shear Strength

140 MPa20.3 ksi
158 MPa22.9 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
120 MPa17.4 ksi

Hardness, Brinell

55 HB
72 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 600°C1,112 °F · Liquidus Temperature 645°C1,193 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

80°C176 °F
65°C149 °F

Same in both: Thermal Conductivity 147 W/m·K84.9 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.7 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

35 % IACS
34.5 % IACS

Electrical Resistivity

4.93×10⁻⁸ Ω·m1.94 µΩ·in
5×10⁻⁸ Ω·m1.97 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

77 / 100
73 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
45%

Weldability

92 / 100
88 / 100

Formability (cold)

88 / 100
56 / 100

Same in both: Brazeability / Solderability 25 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5754

5754-H111 vs 5754-H14 — frequently asked

Is 5754-H14 stronger than 5754-H111?

Yes. 5754-H14 has a typical yield strength of 205 MPa (29.7 ksi) against 110 MPa (16 ksi) for 5754-H111 — about 86% more. Tensile strength is 260 MPa (37.7 ksi) vs 215 MPa (31.2 ksi).

Which condition does FabDigit quote by default, H111 or H14?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5754-H111 or 5754-H14?

5754-H14, by a small margin. Both rate fair for machinability — 50/100 against 40/100 for 5754-H111.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5754-H111 and 5754-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.