FabDigitFabDigit

Aluminum 5454-H112 vs 5454-H32

Aluminum · 5454 temper comparison

5454-H112 and 5454-H32 are two conditions of the same aluminum grade, 5454: H112 (strain hardened from hot working only) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5454-H32 is the stronger of the two: yield strength 205 MPa (29.7 ksi) against 125 MPa (18.1 ksi) for 5454-H112, about 64% more; tensile strength follows at 275 MPa (39.9 ksi) vs 250 MPa (36.3 ksi). In exchange, 5454-H112 is the more ductile: elongation 18% versus 10% for 5454-H32, and 5454-H32 is harder (73 HB vs 65 HB). 5454-H112 runs hotter in service (175°C vs 150°C continuous).

5454-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5454-H32Choose it when strength drives the design.

5454-H112 vs 5454-H32: properties

5454-H1125454-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
275 MPa39.9 ksi

Yield Strength (0.2% offset)

125 MPa18.1 ksi
205 MPa29.7 ksi

Elongation at Break

18%
10%

Shear Strength

160 MPa23.2 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

117 MPa17 ksi
138 MPa20 ksi

Hardness, Brinell

65 HB
73 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 602°C1,116 °F · Liquidus Temperature 646°C1,195 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

137 W/m·K79.2 BTU/hr·ft·°F
134 W/m·K77.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

35 % IACS
34 % IACS

Electrical Resistivity

4.92×10⁻⁸ Ω·m1.94 µΩ·in
5.05×10⁻⁸ Ω·m1.99 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Weldability

92 / 100
90 / 100

Formability (cold)

78 / 100
70 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5454

5454-H112 vs 5454-H32 — frequently asked

Is 5454-H32 stronger than 5454-H112?

Yes. 5454-H32 has a typical yield strength of 205 MPa (29.7 ksi) against 125 MPa (18.1 ksi) for 5454-H112 — about 64% more. Tensile strength is 275 MPa (39.9 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, H112 or H32?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5454-H112 or 5454-H32?

5454-H32. Its machinability rates good (55/100) against fair (48/100) for 5454-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5454-H112 and 5454-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.